WaterBoss Filter Owner’s Manual
6/13/2012
21
900NF Acid Neutralizing Filter Replenishment Procedure, Cont.
Step 4
Add Replenishment Media
A.
Weigh the replenishment media on the analog scale.
B.
Place the funnel into the tank.
C.
Pour the media into the funnel to fill the tank with the measured amount of media.
Step 5
Fill the Tank With Water
A.
Open the main water valve and slowly fill the tank with water up to the bottom of the fill port.
B.
Turn off the water.
C.
Make sure the threads of the fill port are clean and replace the fill plug.
Caution:
Do NOT over-tighten the fill plug.
Step 6
Check for Leaks
A.
Turn on the water to re-pressurize the appliance.
B.
Check for leaks. (See
Check for Leaks
on page 13.)
C.
Fix any leaks.
Step 7
Backwash Neutralizer
A.
Press the Regenerate button.
B.
When the controller reads “01”, slowly rotate the bypass knob clockwise to displace air until
the drain runs steady. Fully rotate the bypass knob clockwise to place the appliance in the
Service position. Let the appliance finish the backwash cycle and return to service.
Содержание 900CF