Installation Steps and Start-Up Procedures, Cont. 

Step 4B: (Optional) Hard Plumbing With Copper 
Fittings 

When preparing the male threaded fittings of the I/O 

adapter, use the following guidelines to avoid damage to the 

plastic pipe threads. 

A.

 

Wrap the threads three times with 1/2-inch (2.5-cm) wide 
Teflon tape. Place each consecutive wrap on top of the 

previous wrap.  

B.

 

To prevent tearing of the tape, use Teflon paste on the 
first two male threads only. The paste lubricates the tape 

and fills the small void areas that might exist between the 
threads. When the joint is complete, there will be a small 

bead of sealant at the fitting interface, which indicates a 
properly joined connection. 

 

 

 

Figure 4: Plumbing Connections 

 

C.

 

Use a union with a threaded connection to facilitate repair of potential leaks in soldered 
joints. 

D.

 

Prepare the copper tail assemblies in advance to enable them to cool prior to final assembly. 

Advance preparation and cooling will prevent heat damage to the plastic pipe threads of the 
adapter. 

E.

 

Ensure that the copper tube is at least 4 inch (10 cm) long. 

F.

 

Turn the fitting counterclockwise until you feel the threads engage and then tighten to 

prevent cross threading. Do NOT overtighten the fittings. 

Caution: Do NOT allow heat from the torch to transfer to the plastic valve component, 

which could be damaged. 

Teflon Tape 

Содержание 900CF

Страница 1: ...OD DE EL LS S 9 90 00 0I IF F 9 90 00 0C CF F A AN ND D 9 90 00 0N NF F O OW WN NE ER R S S M MA AN NU UA AL L A AN ND D I IN NS ST TA AL LL LA AT TI IO ON N G GU UI ID DE E V VE ER RS SI IO ON N 7 7...

Страница 2: ...ss the system is represented as being capable of handling these substances in the system specifications other special treatment of the water supply must be used to remove these substances before they...

Страница 3: ...allation 6 Installation Steps and Start Up Procedures 8 Start Up Procedures 900CF Carbon Filter 15 Start Up Procedures 900NF Acid Neutralizing Filter 16 Start Up Procedures 900IF Iron Filter 17 Settin...

Страница 4: ...appliance installation and operation When calling the HelpLine please have this guide and the serial number of your appliance available WaterBoss 4343 S Hamilton Rd Groveport OH 43125 Warning This app...

Страница 5: ...to regenerate first followed by any filter 3 If dirt sand or large particles are present in the water supply the appropriate WaterBoss filter can eliminate this problem 4 Protect the appliance includi...

Страница 6: ...eded to remove this type of iron Colloidal Iron Not dissolved yet stays in suspension A softener cannot remove this type of iron Water Characteristics Model 900IF Iron Filter requires a pH of 7 or abo...

Страница 7: ...feet 2 4 to 3 0 m of 3 4 inch pipe from the outlet of the appliance to the inlet of the water heater Do Not 1 Do not install if checklist items are not satisfactory See Checklist Before Installation...

Страница 8: ...itting Step 1 Prepare the Placement Area A Make sure the placement area is clean B Turn off the electricity and water supply to the water heater For gas water heaters turn the gas cock to Pilot C Exam...

Страница 9: ...Water Supply A Turn off the water supply B Open the hot and cold water taps to depressurize the lines Step 4 Connect Water Lines Qest fittings are provided to facilitate installation but their use is...

Страница 10: ...When the joint is complete there will be a small bead of sealant at the fitting interface which indicates a properly joined connection Figure 4 Plumbing Connections C Use a union with a threaded conn...

Страница 11: ...fitting D Inspection Cleaning and Priming Inspect the inside of the pipe and fitting sockets and remove dirt grease or moisture with a clean dry cloth If wiping fails to clean the surfaces use a chem...

Страница 12: ...on cycle A Connect the drain line to the drain end cap See Figure 6 with a minimum 5 8 inch I D tubing supplied The size cannot be reduced Note Screw the drain fitting into the drain end cap B Route t...

Страница 13: ...rial D Return the appliance to Service position Turn the knob clockwise until it stops and the arrow points to Service See Figure 8 Note To prevent untreated water from entering your home avoid using...

Страница 14: ...eaters return the gas cock to On E Open a cold water tap and allow the appliance to flush for 20 minutes or until approximately 72 gallons have passed through the appliance This procedure is required...

Страница 15: ...ransformer or use the appliance Step 2 Plug in the Transformer A After 24 hours plug the transformer into an appropriate outlet The transformer is 120 volt 60 cycle AC for locations in North America o...

Страница 16: ...Controller Step 3 Start the Regeneration Cycle Before placing the filter in service backwash the filter to remove fine media particles in the filter bed To backwash the filter start the regeneration...

Страница 17: ...hat the outlet selected is NOT operated by an On Off switch Step 2 Add Water A Slowly fill the media tank until water flows steadily to service B Once filled turn off water and allow the appliance to...

Страница 18: ...Service position The controller will display a number between 01 to 14 This number is the days to next regeneration Step 5 Program the Regeneration Cycle A To ensure reliable performance and optimum...

Страница 19: ...next regeneration or backwash Step 2 Set Time Format Press and hold the Set and Change buttons at the same time for 3 seconds Display reads 12 if the controller is set to display English units or 24 i...

Страница 20: ...ement media P N M050 3 4 inch 19 mm socket with ratchet Replenishment Procedure The replenishment procedure is as follows Step 1 Turn Off the Water A Turn off the water to the appliance B Open a tap t...

Страница 21: ...f the fill port B Turn off the water C Make sure the threads of the fill port are clean and replace the fill plug Caution Do NOT over tighten the fill plug Step 6 Check for Leaks A Turn on the water t...

Страница 22: ...l Cover 1 5 93245 12V Transformer Power Cord 1 6 54303 Cabinet 1 7 54305 Support Panel 1 8 97506 Media tank empty fill plug Models 900IF and 900NF 1 97509 Media tank empty fill plug Model 900CF only C...

Страница 23: ...Plug 1 5 93272 O Ring 1 6 90819 O Ring 2 7 90828 O Ring 1 8 54520 Drive End Cap Assembly Model 900IF 1 95302T BWO BWO Models 900CF and 900NF 9 93870 Screw 4 10 93504 Injector Assembly 1 11 93835 Sleev...

Страница 24: ...The Throat should be pressed flush into the opening in the valve If the Throat is removed it must be replaced with a new one 53224 Injector Nozzle with Over Mold Gasket Together with the Throat 93223...

Страница 25: ...erBoss Filter Owner s Manual 6 13 2012 25 Assembly and Parts Cont Bypass Assembly Available as assembly only Figure 15 Bypass Assembly Part Description Quantity 1 54523 Bypass Assembly 1 2 93838 O Rin...

Страница 26: ...Slide Cam Cover 1 7 93217 Piston Slide Cam 1 8 93583 Drive End Cap 1 9 54202 Piston Slide 1 10 90818 Screw self tapping Model 900IF Only 2 11 54521 Brine Valve Assembly Model 900IF Only 1 12 90821 O R...

Страница 27: ...s Cam Shaft should turn freely before the Motor is assembled 93583 Drive End Cap Seals the two openings on the Main Valve Body The larger diameter opening is sealed with an O Ring used as an axial or...

Страница 28: ...93281 Fill Plug The Fill Plug 93281 seals the media access ports in the Media Tank Care should be taken that the O Ring seal area is kept clean and free of debris Also the O Ring should be in the pro...

Страница 29: ...side of the flange and a spring pressed onto a boss on the other side The O Ring should be free of defects such as cuts or debris on the shaft side 53510 Housing Just inside the entrance hole for the...

Страница 30: ...hutoff Assembly Part Description Quantity 1 54226 Safety Shutoff Valve 1 2 3 8 Retainer Sleeve 1 3 3 8 Plastic Gripper 1 4 3 8 Nut 1 5 Wrist Pin 1 6 10700 IF Float Assembly 1 7 54191 Air Check Assembl...

Страница 31: ...emoved from the elbow body Parts must be reassembled exactly as shown to function properly When connecting the 54315 Brine Valve Elbow 3 8 inch 10 mm plastic tube first assemble the nut gripper and re...

Страница 32: ...tached properly Make sure the controller is pushed all the way onto the drive end cap Defective magnet disk Replace magnet disk Foreign object in valve body Remove foreign object s from the valve body...

Страница 33: ...ogram iron filter regeneration frequency E1 Home not found Cycle power by unplugging the transformer and plugging it back in It will look for Home again Make sure the controller is pushed all the way...

Страница 34: ...hes 14 75 x 18 75 14 75 x 18 75 14 75 x 18 75 Electrical rating 12 VAC 1 phase 60 Hz 12 VAC 1 phase 60 Hz 12 VAC 1 phase 60 Hz Plumbing connections 1 inch MNPT 1 inch MNPT 1 inch MNPT Shipping weight...

Страница 35: ...Notes...