TROUBLESHOOTING GUIDE

TROUBLESHOOTING GUIDE

Содержание Resilience CLGE40

Страница 1: ...TROUBLESHOOTING GUIDE TROUBLESHOOTING GUIDE ...

Страница 2: ...ire device from the line Built in service and maintenance alerts Easy to know when to clean replace the cartridge Designed with the pool owner in mind Designed with the pool owner in mind 2 Bi directional flow sensor Built in temperature salinity sensors Replaceable electrolysis cartridge Control box ...

Страница 3: ...TROUBLESHOOTING TROUBLESHOOTING 3 ...

Страница 4: ...e cartridge and clean it if necessary 3 Disconnect the plug Dismantle the power box connect the plug and check that all the LED is on for 1 sec and then the system error LED is blinking 4 Assemble and turn on the system check if the problem solved Before Troubleshooting Before Troubleshooting 4 ...

Страница 5: ...Check for closed valves pump cavitation faulty pump etc In case you have a variable frequency pump installed increase the flow until the LED is turned off Slightly tilt the cell sideways to remove air bubble Paddle is stuck at the center Dismantle cartridge from cell body and remove scale build up Refer to relevant chapter in manual or appropriate YouTube videos Low salinity Check pool salinity wi...

Страница 6: ...er with a stick If needed add salt according to the salinity table in the installation manual Scale build up inside the cartridge Visually inspect the cartridge for lime scale Clean blades if necessary refer to relevant chapter in manual or appropriate YouTube video Air bubbles in the salinity sensor See NO FLOW slide Other If none of the above resolves the problem replace cartridge 6 ...

Страница 7: ...ystem is OK If water temp is higher than 68 F then temp sensor had failed Temperature sensor failed Replace cartridge Refer to relevant Youtube video COLD WATER COLD WATER LED Turns On when Measured Water temperature is below 68 F When below 68 F 20 c max chlorine output level 50 When below 59 F 15 c max chlorine output level 25 7 ...

Страница 8: ...y Increase salinity levels to 3500 4000 ppm Worn cartridge If none of the above resolves the problem replace the cartridge with a new one Refer to relevant YouTube video CLEAN CELL CLEAN CELL LED Turns On when Chlorine output level doesn t reach the set point and the following parameters are OK Salinity levels above 2400 ppm Water temperature above 68 F 8 ...

Страница 9: ...s to 3500 4000 ppm Blades are worn If none of the above resolves the problem replace the cartridge with a new one check warranty Refer to relevant YouTube video CELL LIFE LOW CELL LIFE LOW LED Turns On when Cell operating hours above 8000 Chlorine output level doesn t reach the set point and the following parameters exist Salinity levels above 2400 ppm Temperature water above 68 F 9 ...

Страница 10: ...ction of the cartridge Clean cartridge refer to relevant chapter in manual or appropriate YouTube video Communication problem between the cartridge and control box Replace the cartridge if problem is not resolved replace the control box SYSTEM ERROR blinking LED SYSTEM ERROR blinking LED LED is Blinking when No communication is detected between the cartridge and control box 10 ...

Страница 11: ...cal connector In case debris has settled there gently remove it and re attach Worn cell scale build up Visually inspect the cartridge to see if blades are dirty or damaged If dirty clean cartridge Refer to relevant chapter in manual or appropriate YouTube video A more profound error occurred Dismantle the power box and turn on if the System Error LED is not blinking replace the power box If it is ...

Страница 12: ...the plug into socket Circulation pump is off Unit should be wired in such a way that it operates only when the circulation pump is on verify that pump is in fact operating Other malfunction in the unit Replace control box No Display power supply does not turn on No Display power supply does not turn on 12 ...

Страница 13: ...fer to the Low Salt warning slide 8 Overheating protection In extreme conditions when the unit identifies overheating it will automatically reduce chlorine production to protect itself Scale build up inside cartridge Clean cartridge refer to relevant chapter in manual or appropriate Youtube video Worn cartridge If none of the above resolves the problem the cartridge may be worn and requires replac...

Страница 14: ...de Top nut leaking Tight the nut Replace the O ring Possible Causes What to do Production problem Old version Replace control box and the O ring to the latest version LEAKING LEAKING TOP NUT CRACKED BROKEN TOP NUT CRACKED BROKEN 14 ...

Страница 15: ...Thank you Thank you ...