LED “no flow” Turns On When:
Flow switch paddle is centered
And / OR
There are air bubbles in the salinity sensor
Gas bubbles
NO FLOW
NO FLOW
Possible Causes
What to do
Air bubbles form in the salinity
sensor
This may happen if there is air in the pipe lines or for a few minutes at
initial startup. Wait until air bubble disappear
Clean filters and strainers
Check for closed valves, pump cavitation, faulty pump etc'
In case you have a variable frequency pump installed, increase the flow
until the LED is turned off
Slightly tilt the cell sideways to remove air bubble
Paddle is stuck at the center
Dismantle cartridge from cell body and remove scale build up. Refer to
relevant chapter in manual or appropriate YouTube videos
Low salinity
Check pool salinity with a stick, if needed add salt according to the
salinity table in the installation manual
Other
If none of the above resolves the problem replace
cartridge
5