WaterBoss Filter Owner’s Manual
6/13/2012
18
Start-Up Procedures—900IF Iron Filter, Cont.
Step 4
Start the Regeneration Cycle
A.
Press and hold the Regenerate button until the controller indicates 01 (flashing). The
regeneration cycle begins. During regeneration, water bypasses the appliance to allow iron
and sediment to wash down the drain through the following six-step process:
1.
First Upflow Backwash
—A rapid upflow of water flushes out the media bed.
2.
Regeneration
—Regenerant is drawn out of the solution cabinet and up through the
media tank, cleaning the media bed and releasing accumulated iron and hydrogen
sulfide.
3.
Slow Rinse
—A slow upflow rinse process that flushes out the regenerant and iron.
4.
Second Upflow Backwash
—This upflow backwash flushes out any remaining
regenerant and sediment from regeneration.
5.
Downflow Clean Water Refill
—Filtered water is directed to the solution cabinet to
prepare the regenerant for the next regeneration sequence.
6.
Return to Service
—Regeneration is complete after approximately 45 minutes and the
appliance is returned to Service position. The controller will display a number between
01 to 14. This number is the days to next regeneration.
Step 5
Program the Regeneration Cycle
A.
To ensure reliable performance and optimum efficiency, program the regeneration cycle to
occur every one to fourteen days. Use the following worksheet to determine the appropriate
frequency for scheduling the regeneration cycle for your appliance. Use the example as a
guide.
B.
On the controller, set the frequency and time of day for regeneration to occur. Follow the
instructions provided in
Setting the Controller
.
Regeneration Cycle Frequency Worksheet
Your Water
Example
Total Iron
_____ ppm x 1 =
____ ppm
2.4 ppm x 1 =
2.4 ppm
+ Manganese*
_____ ppm x 3 =
____ ppm
0.2 ppm x 3 =
0.6 ppm
+ Sulfur
_____ ppm x 5 =
____ ppm
1.0 ppm x 5 =
5.0 ppm
= Total compensated ppm
____ ppm
8.0 ppm
x Gallons per day for one person
75 gal
75 gal
= ppm per person per day
=
____ ppm
600 ppm
x Number of people in household
____ people
3 people
= Daily ppm capacity
____ ppm
1800 ppm
Iron filter capacity
=
5600 ppm
5600 ppm
Daily ppm capacity
= ____
ppm
1800
ppm
= Frequency of regeneration
____ days
3.1 days
Set regeneration frequency
@
____ days
3 days
*If manganese is unknown, multiply the iron and sulfur total by 1.15 to adjust total compensated ppm.