5
FILL
SET
CYCLE 1
DBL REGEN
SET
10%
>
GALLON CAPACITY
SET
AUTO
SOFTENING
SET
CYCLE 2
CYCLE 3
SOFTENING TIME
SET
240:00
MIN
12:00
MIN
BACKWASH
SET
BACKWASH TIME
SET
FILL
SET
15.0 LBS
X1K
GRAINS OF CAPACITY
SET
32.0
SOFTENING
SET
TYPE
1
2
3
4
5
6
7
8
9
10
Service/OEM SOFTENING Screens
Accessed by pressing and holding
NEXT
and
—
simultaneously for three seconds.
Returns to general display after five minutes of inactivity.
Select SOFTENING or FILTERING with + or — buttons.
If you have selected FILTERING, please refer to
“Service/OEM FILTERING screens”, page 7-8.
Set system’s grains of capacity with + or — buttons.
X1K = 1,000 grains.
The default setting is 32.0
Set gallon capacity with + or — buttons.
• AUTO automatically calculates gallon capacity.
• OFF will regen by days override setting only.
• GALS BETWEEN REGEN will regen by specific gallon setting.
• Default setting is AUTO.
Set double regen point with + or — buttons.
If unit’s capacity is overrun by this percentage, the unit will regen
two nights in a row. Default setting is 10%.
Set softening time with + or — buttons.
This is the time between brine tank fill and start of backwash. This
time window allows the salt to dissolve and achieve proper brine
strength. This process will start prior to regen time setting.
Default setting is 240:00 minutes.
Set salt pounds per regen with + or — buttons.
Default setting is 15.0 pounds.
Set backwash time with + or — buttons.
Default setting is 12:00 minutes.
Set second cycle position with + or — buttons.
Set third cycle position with + or — buttons.
Set first cycle position with + or — buttons.
continue to next page
During
FILL
and
SOFTENING
positions,
unit will deliver
soft water.