5

FILL

SET

CYCLE 1

DBL REGEN

SET

10%

>

GALLON CAPACITY

SET

AUTO

SOFTENING

SET

CYCLE 2

CYCLE 3

SOFTENING TIME

SET

240:00

MIN

12:00

MIN

BACKWASH

SET

BACKWASH TIME

SET

FILL

SET

15.0 LBS

X1K

GRAINS OF CAPACITY

SET

32.0

SOFTENING

SET

TYPE

1

2

3

4

5

6

7

8

9

10

Service/OEM SOFTENING Screens

Accessed by pressing and holding 

NEXT

 and 

 simultaneously for three seconds. 

Returns to general display after five minutes of inactivity. 

Select SOFTENING or FILTERING with + or — buttons.

If you have selected FILTERING, please refer to  

“Service/OEM FILTERING screens”, page 7-8.

Set system’s grains of capacity with + or — buttons.

X1K = 1,000 grains. 

The default setting is 32.0

Set gallon capacity with + or — buttons.

• AUTO automatically calculates gallon capacity.

• OFF will regen by days override setting only.

• GALS BETWEEN REGEN will regen by specific gallon setting.

• Default setting is AUTO. 

Set double regen point with + or — buttons.

If unit’s capacity is overrun by this percentage, the unit will regen 

two nights in a row. Default setting is 10%.

Set softening time with + or — buttons.

This is the time between brine tank fill and start of backwash. This 

time window allows the salt to dissolve and achieve proper brine 

strength. This process will start prior to regen time setting.  

Default setting is 240:00 minutes. 

Set salt pounds per regen with + or — buttons.

Default setting is 15.0 pounds. 

Set backwash time with + or — buttons.

Default setting is 12:00 minutes. 

Set second cycle position with + or — buttons.

Set third cycle position with + or — buttons.

Set first cycle position with + or — buttons.

continue to next page

During 

FILL

 and  

SOFTENING

 positions, 

unit will deliver  

soft water. 

Содержание Impression

Страница 1: ...Master Programming Manual for Impression Impression Plus and Impression Twin Models Effective January 2018...

Страница 2: ...REGEN TODAY will alternate with the current screen header if a regen is expected tonight Displays current time Unit defaults to this screen after a reset Displays a unit s remaining capacity This scre...

Страница 3: ...t backlight operation with or buttons Default setting is ON OFF will turn display backlight off after 5 minutes of keypad inactivity Scrolling contact phone number screen Set phone number by using the...

Страница 4: ...or one position to the right Continuing to press the NEXT button will advance to the Contact Name Display Contact name screen Set contact name by using the or buttons Pushing the NEXT button will adva...

Страница 5: ...gallon capacity OFF will regen by days override setting only GALS BETWEEN REGEN will regen by specific gallon setting Default setting is AUTO Set double regen point with or buttons If unit s capacity...

Страница 6: ...ve minutes of inactivity Set fourth cycle position with or buttons Set draw time with or buttons Default setting is 90 00 minutes Set fifth cycle position with or buttons Set final rapid rinse time wi...

Страница 7: ...have selected SOFTENING please refer to Service OEM SOFTENING screens page 5 6 Set gallons of capacity with or buttons To turn off set below 0 OFF does not use metered water to determine a regen and...

Страница 8: ...itions can be programmed into a regeneration An END position triggers the end of a regeneration and a return to service Press and hold CLOCK and buttons simultaneously for three seconds to access OZON...

Страница 9: ...ault setting is OFF WARNING External contact is needed to operate any of the above settings properly If no external contact is connected no setting is needed Set regen time control with or buttons DEL...

Страница 10: ...by this press NEXT Set relay setpoint with or buttons This is the delay time period after regen starts that relay will initially energize 0 indicates an immediate start Set relay setpoint with or butt...

Страница 11: ...lay will be energized while unit is in an error mode To set by this press NEXT Set relay trigger with or buttons FLOW indicates that relay will close whenever flow is detected by the control To set by...

Страница 12: ...enerate Only appears on units set to 1 0T Mode Displays tank transfer history Use or buttons to scroll through last 10 tank transfers Viewed in 1 0T Mode only 1 indicates most recent tank transfer A i...

Страница 13: ...tected or will be the average values measured during generator period of operation AAA Generator current draw in mA VV V Generator voltage in VDC Viewed only if SERVICE OEM is set to OZONE ON Displays...

Страница 14: ...e to detection of an invalid regeneration cycle step Internal software issue 204 LEAK DETECTED 402 POWER DOWN MEMORY Check sum error for operational data and status section of EEPROM memory specific t...

Страница 15: ...15 Notes...

Страница 16: ...1900 Prospect Court Appleton WI 54914 Phone 920 739 9401 Fax 920 739 9406 MAN IMP MASTER Rev A0118...

Отзывы: