MAV DRIVE 1

SET

IN

DELAYED

SET

REGEN

OFF

VALVE TYPE

SET

1.0

AUXILIARY INPUT

SET

OFF

1

MIN

Pre-Service Rinse

SET

OFF

2

3

4

Configuration Screens

Accessed by pressing and holding 

NEXT

 and 

 simultaneously for three seconds. 

Once screen changes, press and hold 

NEXT

 and 

— 

simultaneously again for three seconds. 

Select meter size with + or — buttons.

Set to 1”, 1.25”, 1.5”, 2” or 1.0T (for twin units). Upflow brining will not be an option if set to anything other  than 1” or 1.0T. 

With 1.0T set:

 

• Meter calibration will be fixed.

• MAV 1 setting will not be viewed, but forced to be set to Alternator Mode w/ Immediate Regen and Post Fill Brining.  

• The Backwash-Air regeneration step will not be available.

• Default setting is 1”

Set auxilliary input with + or — buttons.

• IMMED indicates unit will regen immediately.

• DELAY indicates that after a 2 minute signal from external contact, unit will regen at delayed regen time.

• HOLD indicates that unit will not regen while external contacts are closed.

• ALARM indicates that control valve’s internal alarm will sound upon external contact closure.

• Default setting is OFF.

WARNING: External contact is needed to operate any of the above settings properly. If no external contact is 

connected, no setting is needed. 

Set regen time control with + or — buttons.

• DELAYED sets regen to specified regen time.

• DELAY + IMMEDIATE sets regen to occur after 10 minutes of no water usage.

• IMMEDIATE sets an immediate regen upon zero gallons of remaining capacity.

• Default setting is DELAYED.

Set pre-service rinse time with + or — buttons.

This option is only available if the valve type is set to 1.0T (twin). 

Range is 0-20 minutes. Default setting is OFF. 

Set first MAV drive control with + or — buttons.

• ALT A and ALT B are only used in twin configurations (see MAV manual for more details).
• SYSTEM CONTROLLER configures board to operate with the Clack System Controller.
• SEPARATE SOURCE changes state at the start and end of regen cycle.
• NO HARD BYPASS configures MAV as a no hard water bypass.
• TIME changes state at a set time referenced to the start of regen, for a preset duration of time independent    
   of actual regen status. Inactive during alternate regeneration cycle. 
• Default setting is OFF.

WARNING: Leaving valve in ALT A, ALT B or ENABLED without proper hardware will result in errors. 

continue to next page

Only appears 

on units set to 

1.0T Mode

Содержание Impression

Страница 1: ...Master Programming Manual for Impression Impression Plus and Impression Twin Models Effective January 2018...

Страница 2: ...REGEN TODAY will alternate with the current screen header if a regen is expected tonight Displays current time Unit defaults to this screen after a reset Displays a unit s remaining capacity This scre...

Страница 3: ...t backlight operation with or buttons Default setting is ON OFF will turn display backlight off after 5 minutes of keypad inactivity Scrolling contact phone number screen Set phone number by using the...

Страница 4: ...or one position to the right Continuing to press the NEXT button will advance to the Contact Name Display Contact name screen Set contact name by using the or buttons Pushing the NEXT button will adva...

Страница 5: ...gallon capacity OFF will regen by days override setting only GALS BETWEEN REGEN will regen by specific gallon setting Default setting is AUTO Set double regen point with or buttons If unit s capacity...

Страница 6: ...ve minutes of inactivity Set fourth cycle position with or buttons Set draw time with or buttons Default setting is 90 00 minutes Set fifth cycle position with or buttons Set final rapid rinse time wi...

Страница 7: ...have selected SOFTENING please refer to Service OEM SOFTENING screens page 5 6 Set gallons of capacity with or buttons To turn off set below 0 OFF does not use metered water to determine a regen and...

Страница 8: ...itions can be programmed into a regeneration An END position triggers the end of a regeneration and a return to service Press and hold CLOCK and buttons simultaneously for three seconds to access OZON...

Страница 9: ...ault setting is OFF WARNING External contact is needed to operate any of the above settings properly If no external contact is connected no setting is needed Set regen time control with or buttons DEL...

Страница 10: ...by this press NEXT Set relay setpoint with or buttons This is the delay time period after regen starts that relay will initially energize 0 indicates an immediate start Set relay setpoint with or butt...

Страница 11: ...lay will be energized while unit is in an error mode To set by this press NEXT Set relay trigger with or buttons FLOW indicates that relay will close whenever flow is detected by the control To set by...

Страница 12: ...enerate Only appears on units set to 1 0T Mode Displays tank transfer history Use or buttons to scroll through last 10 tank transfers Viewed in 1 0T Mode only 1 indicates most recent tank transfer A i...

Страница 13: ...tected or will be the average values measured during generator period of operation AAA Generator current draw in mA VV V Generator voltage in VDC Viewed only if SERVICE OEM is set to OZONE ON Displays...

Страница 14: ...e to detection of an invalid regeneration cycle step Internal software issue 204 LEAK DETECTED 402 POWER DOWN MEMORY Check sum error for operational data and status section of EEPROM memory specific t...

Страница 15: ...15 Notes...

Страница 16: ...1900 Prospect Court Appleton WI 54914 Phone 920 739 9401 Fax 920 739 9406 MAN IMP MASTER Rev A0118...

Отзывы: