background image

10

cont’d 

RELAY 1 TRIGGER

SET

OFF

RELAY 1 TRIGGER

SET

TIME

RELAY 1 SETPOINT

SET

15

MIN

RELAY 1 DURATION

SET

90:00

MIN

RELAY 1 TRIGGER

SET

GALLONS

RELAY 1 SETPOINT

SET

25

GAL

RELAY 1 DURATION

SET

0:30

MIN

5

Configuration Screens  

 

 

 

 

 

 

 

      

Accessed by pressing and holding 

NEXT

 and 

 simultaneously for three seconds. 

Once screen changes, press and hold 

NEXT

 and 

— 

simultaneously again for three seconds. 

Set first relay trigger with + button. Press + to reach desired triggering event.

If not using a relay, make sure OFF is selected and press 

NEXT.

OFF indicates that no external devices are being used. 
Default is OFF.

continued from previous page

Return to  

General Display

Return to  

General Display

Return to  

General 

Display

Set relay trigger with + or — buttons.

TIME indicates that relay will be energized for a specified 

period of time during regen only. To set by this, press 

NEXT

.

Set relay setpoint with + or — buttons.

This is the delay time period after regen starts that relay 

will initially energize. 0 indicates an immediate start.

Set relay setpoint with + or — buttons.

This is the gallons that will be expended before relay will 

initially energize.

Set relay trigger with + or — buttons.

GALLONS indicates that relay will be energized after a specified number of 

gallons are expended in service position only. To set by this, press 

NEXT.

Set relay duration with + or — buttons.

This is the duration of time, after relay setpoint, that relay 

will remain energized. 

NOTE:

 

Can be all or any part of total regen time, but will 

turn off at end of regen.

Set relay duration with + or — buttons.

This is the duration of time, after relay setpoint, 

that relay will remain energized. Adjustable from 

1 sec to 500 min. 

NOTE:

 Will shut off if a regen is initiated

If using Relay:

1. Push + to engage    

    one of the following   

    Relay Triggers:

       • Time

       • Gallons

       • Regen

       • Error

       • Flow
       • Pulse
2. Press 

NEXT

 to  

    program Setpoints   

    and Durations

continue to next page

Содержание Impression

Страница 1: ...Master Programming Manual for Impression Impression Plus and Impression Twin Models Effective January 2018...

Страница 2: ...REGEN TODAY will alternate with the current screen header if a regen is expected tonight Displays current time Unit defaults to this screen after a reset Displays a unit s remaining capacity This scre...

Страница 3: ...t backlight operation with or buttons Default setting is ON OFF will turn display backlight off after 5 minutes of keypad inactivity Scrolling contact phone number screen Set phone number by using the...

Страница 4: ...or one position to the right Continuing to press the NEXT button will advance to the Contact Name Display Contact name screen Set contact name by using the or buttons Pushing the NEXT button will adva...

Страница 5: ...gallon capacity OFF will regen by days override setting only GALS BETWEEN REGEN will regen by specific gallon setting Default setting is AUTO Set double regen point with or buttons If unit s capacity...

Страница 6: ...ve minutes of inactivity Set fourth cycle position with or buttons Set draw time with or buttons Default setting is 90 00 minutes Set fifth cycle position with or buttons Set final rapid rinse time wi...

Страница 7: ...have selected SOFTENING please refer to Service OEM SOFTENING screens page 5 6 Set gallons of capacity with or buttons To turn off set below 0 OFF does not use metered water to determine a regen and...

Страница 8: ...itions can be programmed into a regeneration An END position triggers the end of a regeneration and a return to service Press and hold CLOCK and buttons simultaneously for three seconds to access OZON...

Страница 9: ...ault setting is OFF WARNING External contact is needed to operate any of the above settings properly If no external contact is connected no setting is needed Set regen time control with or buttons DEL...

Страница 10: ...by this press NEXT Set relay setpoint with or buttons This is the delay time period after regen starts that relay will initially energize 0 indicates an immediate start Set relay setpoint with or butt...

Страница 11: ...lay will be energized while unit is in an error mode To set by this press NEXT Set relay trigger with or buttons FLOW indicates that relay will close whenever flow is detected by the control To set by...

Страница 12: ...enerate Only appears on units set to 1 0T Mode Displays tank transfer history Use or buttons to scroll through last 10 tank transfers Viewed in 1 0T Mode only 1 indicates most recent tank transfer A i...

Страница 13: ...tected or will be the average values measured during generator period of operation AAA Generator current draw in mA VV V Generator voltage in VDC Viewed only if SERVICE OEM is set to OZONE ON Displays...

Страница 14: ...e to detection of an invalid regeneration cycle step Internal software issue 204 LEAK DETECTED 402 POWER DOWN MEMORY Check sum error for operational data and status section of EEPROM memory specific t...

Страница 15: ...15 Notes...

Страница 16: ...1900 Prospect Court Appleton WI 54914 Phone 920 739 9401 Fax 920 739 9406 MAN IMP MASTER Rev A0118...

Отзывы: