flow diagrams
5
Slow rinse
balance of 50 minute cycle
After all the brine has been drawn from the brine
tank, hard water continues to enter thru the valve
inlet - flows around the lower piston groove - thru
the nozzle and orifice - down thru the resin and into
the distributor - up thru the center tube - thru the
center hole in the piston and out the drain line.
7
Settling rinse
5 minutes
VALVE 04UVIE
MSlMIL
•• INE VAlVE
flOW CONTICM.
tNJlCTOlt
IItNf TAMIl
SAlT LEY(
Hard water enters the unit at the valve inlet - flows
around the lower piston groove - down thru the top
of tank passage - downward thru the resin - up the
distributor tube - thru the center hole in the piston -
over the top edge of the piston and out the drain
line.
6
Rapid rinse
10 minutes
Hard water enters the unit at the valve inlet - flows
around the lower piston groove and lower piston land -
down thru the center tube and out the distributor - up
thru the resin - thru the top of tank passage - around
the upper piston groove and out the drain line.
8
Regenerant tank refill
Adjustable4-24minutes
REFILL (SALT DOSE)ADJUSMENT CAM
YAl'lf OlivE ASSEMI(
ItUIN
LlVl
l'
Содержание FF-948-M