DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES) 

GEH50DEEJSC 

GeoSpring

 Pro Hybrid Electric Water Heater

For answers to your Monogram, GE Café

 Series, GE Profile

 Series or 

GE Appliances product questions, visit our website at geappliances.com 
or call GE Answer Center

®

 Service, 800.626.2000.

Specification Revised 3/17

Above illustration intended for dimensional 

reference only. Refer to photograph for 

actual product appearance.

59.5"

60.75"

46.79"

Condensate

Line

38.78"

T&P

Relief

Valve

21.75"

37.33"

T2 Sensor

24.76"

Element

 10.11"

Element

 3.47"

Drain

Valve

GeoSpring

LOCAL INSTALLATION REGULATIONS:

 This water heater must be 

installed in accordance with these instructions, local codes, utility codes, 
utility company requirements or, in the absence of local codes, the latest 
edition of the National Electrical Code. It is available from some local 
libraries or can be purchased from the National Fire Prevention Association, 
Batterymarch park, Quincy, MA 02169 as booklet ANSI/NFPA 70.

INSTALLATION INFORMATION:

 For complete information, see installation 

instructions packed with your water heater.

POWER REQUIREMENTS:

 Check the markings on the rating plate of the 

water heater to be certain the power supply corresponds to the water heater 
requirements.

LOCATION:

 Locate the water heater in a clean dry area as near as practical 

to the area of greatest heated water demand. Long uninsulated hot water lines 
can waste energy and water.

NOTE:

 Because this unit draws in air from the room to heat the water, the 

room must be at least 10' x 10' x 7' (700 cubic feet) or larger. If the room is 
smaller, there must be a louvered door. Louvers should be 240 square inches 
(0.15m2) or greater. If two louvers are used, one should be near the top of 

the door. Place the water heater in such a manner that the air filter, cover 
and front panels can be removed to permit inspection and servicing, such 
as removal of elements or cleaning of the filter. The water heater and water 
lines should be protected from freezing temperatures and high-corrosive 
atmospheres. Do not install the water heater in outdoor, unprotected areas.

Содержание GeoSpring GEH50DEEJSC

Страница 1: ...MA 02169 as booklet ANSI NFPA 70 INSTALLATION INFORMATION For complete information see installation instructions packed with your water heater POWER REQUIREMENTS Check the markings on the rating plate of the water heater to be certain the power supply corresponds to the water heater requirements LOCATION Locate the water heater in a clean dry area as near as practical to the area of greatest heate...

Страница 2: ...ing the adapter to the cold water connections on heater Any heat applied to the hot or cold water connection will permanently damage the dip tube CONDENSATE DRAIN REQUIRED A primary drain pipe must be installed at the top right side of the water heater The primary drain is intended to carry all condensate away TOP FILTER REMOVAL CLEARANCE REQUIREMENTS A minimum 6 clearance is required at the top o...

Страница 3: ...Upper element turns off and compressor turns back on Uses efficient heat pump for majority of heating NOTE Heat pump operating range is 35 F to 120 F VERIFICATION CHECKLIST 1 TANK LOCATION Is room size less than 10x10x7 700 cu ft If yes Louvered door or similar ventilation is needed Back of unit away from wall by 7 inches Front of unit is free and clear Is the water heater level If no add shims un...

Страница 4: ...hour delivery Installs like a standard electric water heater with the same top water and electrical connections making replacing your old standard water heater quick and easy Electronic controls with 4 operating modes plus a vacation setting make it simple to select the temperature and optimal energy savings performance Utilizes heat pump technology to absorb the heat in ambient air and transfers ...

Отзывы: