Page 10 of 34
Page 11 of 34
Doc: Transducer Installation
Version: 2.6 May 2021
Doc: Transducer Installation
Version: 2.6 May 2021
TRANSDUCER INSTALLATION MANUAL
TRANSDUCER INSTALLATION MANUAL
3 MOUNTING OPTIONS
3.1. THROUGH HULL MOUNTING
When mounting the transducer, ensure it is accurately running parallel to the keel. See
below.
WASSP
Transducer
WASSP
Transducer
120°
Beam
Angle
300 meters
100 meters
Depth
Avoid mounting another transducer in the vicinity
of the WASSP Transducer, especially along the line of the beam.
VIEWED FROM ABOVE
Location must be such that
beam is clear of hull.
Figure 4. Through Hull Transducer Mounting
AFT
90°
Transducer
90°
90°
FORWARD
HORIZONTAL PLANE
Keel
Looking from above (not to scale)
Mounting Brackets
Figure 5. Positioning the Transducer on the Vessel Hull
CAUTION: The above mounting example is provided as a guide. WASSP Ltd.
recommend that a reputable boat builder is used to install the transducer to
prevent damage to the vessel’s hull.
3.2. POLE MOUNTING
The transducer can be used with a temporary mounting assembly. The assembly would
typically incorporate transducer, and a position and motion sensor, and be deployed on
a rigid mount over the side or the stern of the vessel such that it can be raised / lowered
when required.
AFT
90°
90°
90°
FORWARD
HORIZONTAL PLANE
Keel
Looking from above (not to scale)
GPS
Transducer
Figure 6. Pole Transducer Mounting
CAUTION: The above mounting example is provided as a guide. WASSP
Ltd. recommend that a reputable boat builder is used to fabricate the pole
mount assembly.
Any flex in the pole mount during operation will introduce errors.