![Wassp WMB-X230 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/wassp/wmb-x230/wmb-x230_installation-manual_3495810015.webp)
Page 28 of 34
Page 29 of 34
Doc: Transducer Installation
Version: 2.6 May 2021
Doc: Transducer Installation
Version: 2.6 May 2021
TRANSDUCER INSTALLATION MANUAL
TRANSDUCER INSTALLATION MANUAL
7.3. TRANSDUCER CABLE
The transducer cable consists of seven CAT-5 cables and one
screened pair for the transmit connection.
To fit the RJ-45 connectors and cable through the gland, no
special preparation is required.
The WASSP transceiver cable end has the RJ-45 connectors
fitted with “staggered” cable lengths. This allows each RJ-45
connector and its associated cable to be fed through the gland
fitting easily.
Commencing with the black RJ-45 cable and black transmit
cable, feed each cable in turn through the gland, finishing off
with the grey RJ-45 connector and cable.
Complete fitting and tightening the gland as shown in
10. Mounting the Gland Assembly" on page 26.
NOTE: Colour code for transmit cable
conductors: White, Black and Green.
CAUTION: DO NOT STRAIN THE TRANSDUCER
CABLE!
Forcing the cable to bend, twist, or stretch
beyond its means will damage the transducer
and impair performance.
Once the transducer has been installed, ensure
that the transducer cable is not under tension.
Use cable ties (or similar) to secure the cable as
necessary.
Figure 13. Gland Assembly
- Cable Connectors
7.3.1. Replacing / Repairing an RJ-45 Connector
If one or more of the RJ-45 connectors gets damaged during the installation process,
the connector can be easily replaced. Wiring details and colour codes used are shown
below.
Scr
een / drain wi
re
Blue and Blue Whit
e
Brown and Br
own / White
Gr
een and Gr
een / White
Orange and Orange / White
The CAT5E cables used in the transducer
cable follow standard CAT5 colour codes
but the RJ-45 plug wiring is specific to the
WASSP transceiver and does NOT conform
to T568A or B:
RJ-45 Plug Pin
Number
CAT 5 conductor colour
1
Orange
2
Orange / White
3
Green
4
Green / White
5
Blue
6
Blue / White
7
Brown
8
Brown / White
Case
Screen / drain wire (solder)
Pin #8
Pin #1
The screen / drain wire should be soldered onto
the side of the RJ-45 connector. Scratch the side
of the connector with something sharp before
soldering to assist with the join.