7 Start-up / Installation
Check that the mains voltage and the voltage requirements of the mixer are the
same, then plug in the power cable.
Only for Wamix-Injector IV:
Install a compressed air line in accordance with the technical data. Be sure to use the
correct hose size if the line is long (inside diameter min. 6 mm). Provide a servicing unit for
each line and use a pressure regulator to maintain a constant pressure.
Accidental mixing is not possible because the motor cannot start until the
beaker is held to the rim by the vacuum. The mixing time also needs to be set.
Before you start your vacuum mixer, make sure that the safety hook has
been fastened under the unit. Push the hook to the wall using the slot and
fasten the safety hook to the wall. Than retighten the screw on the chassis
to prevent it coming loose.
Warning: Use only beakers with the new curved seal (171708).
When using the 115 V version you have to install the power pack Order no.
171976. Therefore you plug in the conductor of the Wamix into the socket
(Pos.1) of the power pack. The conductor of the power pack ( Pos.2) has to
be pluged into the house socket. In order to mount the power pack at the
table stand please use the enclosed screws M6.
11
Pos. 2
Pos. 1