3.6
Wärtsilä 9L32, 750 rpm
ME
SCR
mode
DE
SCR
mode
AE
SCR
mode
ME
IMO
Tier 2
DE
IMO
Tier 2
AE
IMO
Tier 2
Wärtsilä 9L32
750
580
750
580
750
580
750
580
750
580
750
580
RPM
kW/cyl
Engine speed
Cylinder output
5220
5220
5220
5220
5220
5220
kW
Engine output
2.88
2.88
2.88
2.88
2.88
2.88
MPa
Mean effective pressure
Combustion air system (Note 1)
9.12
9.42
9.42
9.12
9.42
9.42
kg/s
Flow at 100% load
45
45
45
45
45
45
°C
Temperature at turbocharger intake, max.
55
55
55
55
55
55
°C
Air temperature after air cooler (TE 601)
Exhaust gas system (Note 2)
9.4
9.7
9.7
9.4
9.7
9.7
kg/s
Flow at 100% load
8.1
8.1
8.1
8.4
8.8
8.8
kg/s
Flow at 85% load
7.3
7.4
7.4
7.3
8.0
8.0
kg/s
Flow at 75% load
5.0
5.4
5.4
5.0
5.4
5.4
kg/s
Flow at 50% load
370
350
350
370
350
350
°C
Temperature after turbocharger, 100% load
(TE 517)
340
340
340
330
320
320
°C
Temperature after turbocharger, 85% load
(TE 517)
340
340
340
340
320
320
°C
Temperature after turbocharger, 75% load
(TE 517)
350
360
360
350
360
360
°C
Temperature after turbocharger, 50% load
(TE 517)
5.0
5.0
5.0
5.0
5.0
5.0
kPa
Backpressure, max.
787
787
787
787
787
787
mm
Calculated pipe diameter for 35m/s
Heat balance (Note 3)
660
674
674
660
674
674
kW
Jacket water, HT-circuit
1217
1199
1199
1217
1199
1199
kW
Charge air, HT-circuit
734
722
722
734
722
722
kW
Charge air, LT-circuit
594
608
608
594
608
608
kW
Lubricating oil, LT-circuit
165
165
165
165
165
165
kW
Radiation
Fuel system (Note 4)
700±50
700±50
700±50
700±50
700±50
700±50
kPa
Pressure before injection pumps (PT 101)
5.6
5.6
5.6
5.6
5.6
5.6
m
3
/h
Engine driven pump capacity (MDF only)
5.3
5.3
5.3
5.3
5.3
5.3
m
3
/h
Fuel flow to engine (without engine driven
pump), approx.
16...24
16...24
16...24
16...24
16...24
16...24
cSt
HFO viscosity before engine
140
140
140
140
140
140
°C
HFO temperature before engine, max. (TE
101)
2.0
2.0
2.0
2.0
2.0
2.0
cSt
MDF viscosity, min
45
45
45
45
45
45
°C
MDF temperature before engine, max. (TE
101)
184
185
185
183
183
184
g/kWh
Fuel consumption at 100% load, HFO
183
184
185
180
182
183
g/kWh
Fuel consumption at 85% load, HFO
183
184
185
180
182
183
g/kWh
Fuel consumption at 75% load, HFO
Wärtsilä 32 Product Guide - a21 - 7 September 2016
3-17
3. Technical Data
Wärtsilä 32 Product Guide
Содержание WARTSILA32
Страница 18: ...This page intentionally left blank...
Страница 72: ...This page intentionally left blank...
Страница 130: ...This page intentionally left blank...
Страница 150: ...This page intentionally left blank...
Страница 186: ...This page intentionally left blank...
Страница 204: ...This page intentionally left blank...
Страница 210: ...This page intentionally left blank...
Страница 216: ...This page intentionally left blank...
Страница 238: ...This page intentionally left blank...
Страница 246: ...This page intentionally left blank...
Страница 248: ...This page intentionally left blank...
Страница 251: ......
Страница 252: ......
Страница 253: ......