DE
SCR
mode
AE
SCR
mode
DE
IMO
Tier 2
AE
IMO
Tier 2
Wärtsilä 9L32
720
560
720
560
720
560
720
560
RPM
kW/cyl
Engine speed
Cylinder output
182
183
180
182
g/kWh
Fuel consumption at 75% load, MDF
190
191
186
190
g/kWh
Fuel consumption at 50% load, MDF
19.2
19.3
19.2
19.3
kg/h
Clean leak fuel quantity, MDF at 100% load
3.8
3.9
3.8
3.9
kg/h
Clean leak fuel quantity, HFO at 100% load
Lubricating oil system
500
500
500
500
kPa
Pressure before bearings, nom. (PT 201)
30
30
30
30
kPa
Suction ability main pump, including pipe loss, max.
50
50
50
50
kPa
Priming pressure, nom. (PT 201)
30
30
30
30
kPa
Suction ability priming pump, including pipe loss,
max.
63
63
63
63
°C
Temperature before bearings, nom. (TE 201)
79
79
79
79
°C
Temperature after engine, approx.
108
108
108
108
m³/h
Pump capacity (main), engine driven
96
96
96
96
m³/h
Pump capacity (main), stand-by
21.6 /
25.9
21.6 /
25.9
21.6 /
25.9
21.6 /
25.9
m³/h
Priming pump capacity, 50Hz/60Hz
2.3
2.3
2.3
2.3
m³
Oil volume, wet sump, nom.
6.8
6.8
6.8
6.8
m³
Oil volume in separate system oil tank, nom.
0.35
0.35
0.35
0.35
g/kWh
Oil consumption (100% load), approx.
2060
2060
2060
2060
l/min
Crankcase ventilation flow rate at full load
0.1
0.1
0.1
0.1
kPa
Crankcase ventilation backpressure, max.
8.5...9.5
8.5...9.5
8.5...9.5
8.5...9.5
liters
Oil volume in turning device
1.9
1.9
1.9
1.9
liters
Oil volume in speed governor
Cooling water system
High temperature cooling water system
250 +
static
250 +
static
250 +
static
250 +
static
kPa
Pressure at engine, after pump, nom. (PT 401)
530
530
530
530
kPa
Pressure at engine, after pump, max. (PT 401)
77
77
77
77
°C
Temperature before cylinders, approx. (TE 401)
96
96
96
96
°C
HT-water out from engine, nom (TE402) (single stage
CAC)
96
96
96
96
°C
HT-water out from engine, nom (TE432) (two stage
CAC)
85
85
85
85
m³/h
Capacity of engine driven pump, nom.
100
100
100
100
kPa
Pressure drop over engine, total (single stage CAC)
150
150
150
150
kPa
Pressure drop over engine, total (two stage CAC)
100
100
100
100
kPa
Pressure drop in external system, max.
70...150
70...150
70...150
70...150
kPa
Pressure from expansion tank
0.56
0.56
0.56
0.56
m³
Water volume in engine
Low temperature cooling water system
Wärtsilä 32 Product Guide - a21 - 7 September 2016
3-15
3. Technical Data
Wärtsilä 32 Product Guide
Содержание WARTSILA32
Страница 18: ...This page intentionally left blank...
Страница 72: ...This page intentionally left blank...
Страница 130: ...This page intentionally left blank...
Страница 150: ...This page intentionally left blank...
Страница 186: ...This page intentionally left blank...
Страница 204: ...This page intentionally left blank...
Страница 210: ...This page intentionally left blank...
Страница 216: ...This page intentionally left blank...
Страница 238: ...This page intentionally left blank...
Страница 246: ...This page intentionally left blank...
Страница 248: ...This page intentionally left blank...
Страница 251: ......
Страница 252: ......
Страница 253: ......