Technical Manual LAZ 5100 / ES 5100
INSTALLATION, CARE AND MAINTENANCE
TH 52 603 8001 EN Rev.: S
Technical Manual LAZ 5100 / ES 5100
5-13
To alter the Protocol, press the following keys:
Call up the
INTERFACES
SUB-MENU
as described previously
CURSOR
(6x, to mark the word
Protocol
)
ENTER
(1x, to mark the selected Protocol)
CURSOR
or
(to alter the Protocol)
ENTER
(1x, to confirm selection)
ESCAPE
(2x, to leave the
MENU
)
Note, that the Protocol ELAC is only applicable for dual channel units, see
also chapter 0 Description of Interfaces.
To alter the recording display time on the LCD – Screen, press the following keys
Call up the
Display 15 min
Sub Menu
as described previously
Enter
(1x), to mark “ON” or “OFF”
Cursor
to alter the setting
Enter
(1x), to confirm the selection
Escape
(2x), to leave the
Menu
Once the initial system settings have been made they need only be altered if for
example a second transducer is added or if the original transducer is replaced with
one of a different frequency.
If a second transducer is added at a later date, parameters must be entered in the
channel 2 sub-menu. The parameters for channel 1 must not be altered.
(See installation instruction UN 52 590 4001 for the integration of the second
channel).
If the original transducer is replaced and the replacement is fitted at a different
location, the parameters must be altered accordingly.
5.1.5 Power
Adjust
This adjust feature allows the authorised service person to alter the transmitting power
according to cable length on board.