![WarmFlow A Series Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/warmflow/a-series/a-series_user-instructions_3395043006.webp)
Page 4
Heat is extracted from the air by blowing air through a finned radiator, known as the evaporator,
with a fan. The extracted energy from the air is transferred into the refrigerant which circulates
around the evaporator. The heat pump then converts this low grade heat to a high grade by
compressing the refrigerant using the compressor. The compression of the refrigerant increases
the pressure and the temperature. This high grade heat is then transferred to the heating system
via another heat exchanger known as the condenser. The heat can now be used to provide space
heating and DHW. The pressure of the refrigerant is then released through a throttling valve
known as the expansion valve which also causes the temperature to drop and allows the cycle to
start over again.
1.4 Product Data
Table 1 Product data
Product Data
AS01-R32
AS02-R32
AS03-R32
Dimensions
(mm)
Width
1002
953
997
Depth
490
460
437
Height
805
915
1315
Weight (kg)
90
108
140
Electrical Supply
230V Single Phase
@50Hz
230V Single Phase
@50Hz
230V Single Phase
@50Hz
Maximum Current (Amps)
13
22
33
Nominal Sound Level (dBA)*
37 - 54
42 - 55
44 - 58
Performance
COP @ A7W35
4.58
4.35
4.67
COP @ A2W30
4.18
3.46
3.74
COP @ A7W27
6.10
5.76
5.37
COP @ A12W24
8.58
8.39
7.37
COP @ A-7W34
3.11
2.95
2.71
COP @ A7W55
2.68
2.67
2.51
COP @ A-10W55
1.90
1.69
1.94
Heat Output Range
2 - 8kW
5 - 12kW
7 - 20kW
ErP Efficiency Class
(35°C / 55°C)^
A+++ / A++
A++ / A++
A++ / A++
Operating Temp.
(
◦
C)
Ambient Air, min/max
-25/43
-25/52
-25/52
Heating Flow, min/max
20/65
20/65
20/65
Flow Rates (l/m)
Heating, min/max
10/20
16/30
28/60
Fluid Content (l)
1.0
1.53
2.51
Refrigerant
Type
R32
R32
R32
Charge (kg)
1.30
1.70
2.00
Connections
Heating Flow & Return
1” female BSP
1” female BSP
1 ¼” female BSP
*Nominal Sound Levels have been independently tested in accordance with EN 12102.
^ ErP ratings have been independently tested in accordance with EN 14825.
Содержание A Series
Страница 36: ...Page 34 Figure 24 AS02 R32 Casing Dimensions Heating Connection Locations FRONT SIDE TOP...
Страница 40: ...Page 38 Figure 26 Heating DHW Schematic Figure 27 Heating Only Schematic...
Страница 70: ...Page 68 7 APPENDIX B WIRING DIAGRAMS...
Страница 71: ...Page 69...
Страница 72: ...Page 70 This page is intentionally left blank...
Страница 74: ...Page 72 This page is intentionally left blank...
Страница 76: ...Page 74...
Страница 77: ...Page 75...
Страница 78: ...Page 76...
Страница 79: ...Page 77...
Страница 80: ...Page 78...
Страница 81: ...Page 79...
Страница 82: ...Page 80...
Страница 83: ...Page 81...
Страница 84: ...Page 82...
Страница 85: ...Page 83...
Страница 86: ...Page 84...
Страница 87: ...Page 85...