Preparation

The electrician should review the electrical page 
of your WCS Design Drawings and note necessary 
materials, locations, voltage and amperage of all 
electrical components.

 

Tubing and Labeling

Adhere the provided labels to each supply and  
return loop beneath the manifold. Appropriate use  
of these labels will assist in any diagnostic issues. 
These color-coded labels coincide with the color 
labels on the side of the Manifold Controller (MC)  
and those displayed in your WCS Design Drawings.

 

Controls

Warmboard Controls consist of the following: 

 

f

120 VAC thermostats (one per heating zone)   

 

f

120 VAC Manifold Controller (one per manifold)

 

f

24 volt solenoid valve actuators (one per loop)

 

f

Smart Reset Controller (inside Warmsource-E) 

Installing the MC

 

f

Use the provided screws to mount each Manifold 
Controller (MC) inside the manifold cabinet specified 
in the WCS Design Drawings

 

f

Plug the MC into the nearby 120 VAC outlet

 

Installing the Actuators

 

f

Attach actuators to each port on the return manifold

 

f

Connect each actuator wire to the appropriate port 
on the side of the MC, which is pre-labeled and color 
coded. Refer to the WCS Design Drawings as needed

MANIFOLD CABINET

Before installing the controls, you 

MUST

 disable 

Construction Mode by removing the jumper on 
the SRC.

Set the temperature gauge on the front of 
Warmsource-E to 138˚F, though you may set this 
lower if desired.

Содержание Comfort System

Страница 1: ...For use with Warmsource E electric boiler WARMBOARD COMFORT SYSTEM 0622 Installation Guide...

Страница 2: ...e the ambient air temperature near the Warmsource E does not exceed 90 F 32 C during operation 6 Reference the Electro Boiler Manual for allowable mineral levels and water quality Filtered water or a...

Страница 3: ...s list can be a helpful when working with Warmboard S and WCS f Foundation and joist f Install Warmboard S f Install tubing some loops before walls f Frame walls roof sheeting f Install tubing manifol...

Страница 4: ...be reset with a bike pump and ball valve in the closed position f Backflow preventer required by code in many jurisdictions prevents water in the closed loop system from mixing with the domestic wate...

Страница 5: ...e piping can be found in the WCS Design Drawings f Pressure test all distribution lines for 15 minutes at 100 PSI International Mechanical Code section 1208 1 Minimum Clearances This illustration show...

Страница 6: ...it Air Eliminator 51 2 331 2 33 4 41 2 253 8 1 11 4 conduit 1 2 3 4 conduit 131 4 51 2 21 4 61 8 3 41 8 91 2 Pressure Relief Drain connection 3 4 NPT 1 11 4 conduit Air Eliminator 51 2 331 2 33 4 41 2...

Страница 7: ...all studs then fasten the unit into place Warmsource E weighs 155lbs and requires two individuals to move safely Connections f Plumb the cold water line to the backflow preventer and the pressure redu...

Страница 8: ...nue filling the system with water for 10 15 minutes until no air is seen or heard escaping the hose f Close the fast fill lever then slowly close hose bib A f Ensure the pressure gauge located inside...

Страница 9: ...lug the white Construction Mode jumper into the Sensor 2 terminal The boiler temperature can be adjusted if a higher temperature is desired Warmsource E will reach the target temperature in about 10 m...

Страница 10: ...per heating zone f 120 VAC Manifold Controller one per manifold f 24 volt solenoid valve actuators one per loop f Smart Reset Controller inside Warmsource E Installing the MC f Use the provided screws...

Страница 11: ...m to behave inaccurately If there are any discrepancies regarding the thermostat or zoning contact us immediately f Remove the appropriate thermostat from the box f Grip the face of the thermostat by...

Страница 12: ...connection AC1 Fan on the Smart Reset Controller SRC f Connect the wires from the AC unit to the terminal block accordingly RC 24 volt power red wire Y Cooling Call yellow wire G Fan green wire f To...

Страница 13: ...nutes the green lights will turn blue indicating that the actuators have opened and water is flowing to the zone f If something does not appear to be working properly consult your Warmboard Engineered...

Страница 14: ...EXCLUDED FAILURE TO INSTALL WARMBOARD PRODUCTS ACCORDING TO MANUFACTURER S INSTRUCTIONS WILL VOID ALL APPLICABLE WARRANTIES IT IS EXPRESSLY UNDERSTOOD THAT WARMBOARD IS NOT RESPONSIBLE FOR ANY CONSEQU...

Отзывы: