Preparation
The electrician should review the electrical page
of your WCS Design Drawings and note necessary
materials, locations, voltage and amperage of all
electrical components.
Tubing and Labeling
Adhere the provided labels to each supply and
return loop beneath the manifold. Appropriate use
of these labels will assist in any diagnostic issues.
These color-coded labels coincide with the color
labels on the side of the Manifold Controller (MC)
and those displayed in your WCS Design Drawings.
Controls
Warmboard Controls consist of the following:
f
120 VAC thermostats (one per heating zone)
f
120 VAC Manifold Controller (one per manifold)
f
24 volt solenoid valve actuators (one per loop)
f
Smart Reset Controller (inside Warmsource-E)
Installing the MC
f
Use the provided screws to mount each Manifold
Controller (MC) inside the manifold cabinet specified
in the WCS Design Drawings
f
Plug the MC into the nearby 120 VAC outlet
Installing the Actuators
f
Attach actuators to each port on the return manifold
f
Connect each actuator wire to the appropriate port
on the side of the MC, which is pre-labeled and color
coded. Refer to the WCS Design Drawings as needed
MANIFOLD CABINET
Before installing the controls, you
MUST
disable
Construction Mode by removing the jumper on
the SRC.
Set the temperature gauge on the front of
Warmsource-E to 138˚F, though you may set this
lower if desired.