background image

6

1.800.556.0595

 

for assistance 

SPECIFICATION

5

1/2

"

33

1/2

"

3

3/4

"

4

1/2

"

25

3/8

"

1" – 1

1/4

"

conduit

1/2

" – 

3/4

"

conduit

13

1/4

"

5

1/2

"

2

1/4

"

6

1/8

"

3"

4

1/8

"

9

1/2

"

Pressure Relief

Drain connection

3/4

" NPT

1" – 1

1/4

"

conduit

Air Eliminator

5

1/2

"

33

1/2

"

3

3/4

"

4

1/2

"

25

3/8

"

1" – 1

1/4

"

conduit

1/2

" – 

3/4

"

conduit

13

1/4

"

5

1/2

"

2

1/4

"

6

1/8

"

3"

4

1/8

"

9

1/2

"

Pressure Relief

Drain connection

3/4

" NPT

1" – 1

1/4

"

conduit

Air Eliminator

5

1/2

"

33

1/2

"

3

3/4

"

4

1/2

"

25

3/8

"

1" – 1

1/4

"

conduit

1/2

" – 

3/4

"

conduit

13

1/4

"

5

1/2

"

2

1/4

"

6

1/8

"

3"

4

1/8

"

9

1/2

"

Pressure Relief

Drain connection

3/4

" NPT

1" – 1

1/4

"

conduit

Air Eliminator

Top View

Front View

Bottom View

Содержание Comfort System

Страница 1: ...For use with Warmsource E electric boiler WARMBOARD COMFORT SYSTEM 0622 Installation Guide...

Страница 2: ...e the ambient air temperature near the Warmsource E does not exceed 90 F 32 C during operation 6 Reference the Electro Boiler Manual for allowable mineral levels and water quality Filtered water or a...

Страница 3: ...s list can be a helpful when working with Warmboard S and WCS f Foundation and joist f Install Warmboard S f Install tubing some loops before walls f Frame walls roof sheeting f Install tubing manifol...

Страница 4: ...be reset with a bike pump and ball valve in the closed position f Backflow preventer required by code in many jurisdictions prevents water in the closed loop system from mixing with the domestic wate...

Страница 5: ...e piping can be found in the WCS Design Drawings f Pressure test all distribution lines for 15 minutes at 100 PSI International Mechanical Code section 1208 1 Minimum Clearances This illustration show...

Страница 6: ...it Air Eliminator 51 2 331 2 33 4 41 2 253 8 1 11 4 conduit 1 2 3 4 conduit 131 4 51 2 21 4 61 8 3 41 8 91 2 Pressure Relief Drain connection 3 4 NPT 1 11 4 conduit Air Eliminator 51 2 331 2 33 4 41 2...

Страница 7: ...all studs then fasten the unit into place Warmsource E weighs 155lbs and requires two individuals to move safely Connections f Plumb the cold water line to the backflow preventer and the pressure redu...

Страница 8: ...nue filling the system with water for 10 15 minutes until no air is seen or heard escaping the hose f Close the fast fill lever then slowly close hose bib A f Ensure the pressure gauge located inside...

Страница 9: ...lug the white Construction Mode jumper into the Sensor 2 terminal The boiler temperature can be adjusted if a higher temperature is desired Warmsource E will reach the target temperature in about 10 m...

Страница 10: ...per heating zone f 120 VAC Manifold Controller one per manifold f 24 volt solenoid valve actuators one per loop f Smart Reset Controller inside Warmsource E Installing the MC f Use the provided screws...

Страница 11: ...m to behave inaccurately If there are any discrepancies regarding the thermostat or zoning contact us immediately f Remove the appropriate thermostat from the box f Grip the face of the thermostat by...

Страница 12: ...connection AC1 Fan on the Smart Reset Controller SRC f Connect the wires from the AC unit to the terminal block accordingly RC 24 volt power red wire Y Cooling Call yellow wire G Fan green wire f To...

Страница 13: ...nutes the green lights will turn blue indicating that the actuators have opened and water is flowing to the zone f If something does not appear to be working properly consult your Warmboard Engineered...

Страница 14: ...EXCLUDED FAILURE TO INSTALL WARMBOARD PRODUCTS ACCORDING TO MANUFACTURER S INSTRUCTIONS WILL VOID ALL APPLICABLE WARRANTIES IT IS EXPRESSLY UNDERSTOOD THAT WARMBOARD IS NOT RESPONSIBLE FOR ANY CONSEQU...

Отзывы: