background image

NOTICE:

 Customer is solely responsible for determining whether the 

products and the information contained in this installation guide are 
appropriate for Customer’s use and are in compliance with applicable laws 
because the applicable laws related to the installation and use of this 
product may vary from one location to another and may change with time.  
Customer represents and warrants that Customer is required to check 
current local laws, building codes and other local requirements and that all 
local requirements will be adhered to in connection with the installation of 
this product.  

NO EXPRESS WARRANTIES ARE GIVEN EXCEPT FOR ANY APPLICABLE 
WRITTEN WARRANTIES SPECIFICALLY PROVIDED BY WARMBOARD.  
ALL IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY 
AND FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY 
EXCLUDED.  FAILURE TO INSTALL WARMBOARD PRODUCTS ACCORDING 
TO MANUFACTURER’S INSTRUCTIONS WILL VOID ALL APPLICABLE 
WARRANTIES.  IT IS EXPRESSLY UNDERSTOOD THAT WARMBOARD IS 
NOT RESPONSIBLE FOR ANY CONSEQUENTIAL OR OTHER DAMAGES 
THAT MAY ARISE FROM USING WARMBOARD PRODUCTS OR 
COMPONENTS.

Warmboard assumes no obligation or liability for the information contained 
in this document.  The Customer assumes all risks as to the use of this 
product.  Customer’s exclusive remedy or any claim (including any claim 
for negligence, strict liability, or tort, without limitation) shall be limited 
to the warranty coverage expressly provided in Warmboard’s warranty 
documents.  Failure to stringently adhere to any of the recommended 
procedures of this installation guide and/or any other Warmboard 
document related to this product shall release Warmboard of all liability 
with respect to this product or the use thereof. 

For complete warranty information please call 1.800.556.0595  
or visit warmboard.com

KEEP OUT OF REACH OF CHILDREN

Содержание Comfort System

Страница 1: ...For use with Warmsource E electric boiler WARMBOARD COMFORT SYSTEM 0622 Installation Guide...

Страница 2: ...e the ambient air temperature near the Warmsource E does not exceed 90 F 32 C during operation 6 Reference the Electro Boiler Manual for allowable mineral levels and water quality Filtered water or a...

Страница 3: ...s list can be a helpful when working with Warmboard S and WCS f Foundation and joist f Install Warmboard S f Install tubing some loops before walls f Frame walls roof sheeting f Install tubing manifol...

Страница 4: ...be reset with a bike pump and ball valve in the closed position f Backflow preventer required by code in many jurisdictions prevents water in the closed loop system from mixing with the domestic wate...

Страница 5: ...e piping can be found in the WCS Design Drawings f Pressure test all distribution lines for 15 minutes at 100 PSI International Mechanical Code section 1208 1 Minimum Clearances This illustration show...

Страница 6: ...it Air Eliminator 51 2 331 2 33 4 41 2 253 8 1 11 4 conduit 1 2 3 4 conduit 131 4 51 2 21 4 61 8 3 41 8 91 2 Pressure Relief Drain connection 3 4 NPT 1 11 4 conduit Air Eliminator 51 2 331 2 33 4 41 2...

Страница 7: ...all studs then fasten the unit into place Warmsource E weighs 155lbs and requires two individuals to move safely Connections f Plumb the cold water line to the backflow preventer and the pressure redu...

Страница 8: ...nue filling the system with water for 10 15 minutes until no air is seen or heard escaping the hose f Close the fast fill lever then slowly close hose bib A f Ensure the pressure gauge located inside...

Страница 9: ...lug the white Construction Mode jumper into the Sensor 2 terminal The boiler temperature can be adjusted if a higher temperature is desired Warmsource E will reach the target temperature in about 10 m...

Страница 10: ...per heating zone f 120 VAC Manifold Controller one per manifold f 24 volt solenoid valve actuators one per loop f Smart Reset Controller inside Warmsource E Installing the MC f Use the provided screws...

Страница 11: ...m to behave inaccurately If there are any discrepancies regarding the thermostat or zoning contact us immediately f Remove the appropriate thermostat from the box f Grip the face of the thermostat by...

Страница 12: ...connection AC1 Fan on the Smart Reset Controller SRC f Connect the wires from the AC unit to the terminal block accordingly RC 24 volt power red wire Y Cooling Call yellow wire G Fan green wire f To...

Страница 13: ...nutes the green lights will turn blue indicating that the actuators have opened and water is flowing to the zone f If something does not appear to be working properly consult your Warmboard Engineered...

Страница 14: ...EXCLUDED FAILURE TO INSTALL WARMBOARD PRODUCTS ACCORDING TO MANUFACTURER S INSTRUCTIONS WILL VOID ALL APPLICABLE WARRANTIES IT IS EXPRESSLY UNDERSTOOD THAT WARMBOARD IS NOT RESPONSIBLE FOR ANY CONSEQU...