GETTING STARTED

Table of Contents

 

f

Getting Started 

Page 2

 

f

WCS Preparation 

Page 3

 

f

Plumbing and Mechanical 

Page 4

 

f

Warmsource-E Preparation 

Page 5

 

f

Warmsource-E Specification 

Page 6

 

f

Warmsource-E Installation 

Page 7

 

f

Filling and Purging 

Page 8

 

f

Construction Mode 

Page 9

 

f

Manifold Cabinet 

Page 10

 

f

Thermostats 

Page 11

 

f

Air Conditioning 

Page 12

 

f

Testing the System 

Page 13

Installation Highlights

1

  This boiler has been sized and engineered  

for 240 volt, single-phase residential wiring.  

DO NOT

 use 208 volt. 

ONLY

 use copper wiring.

2

  WCS uses proprietary, plug-and-play controls 

including thermostats, Manifold Controllers and 
Smart Reset Controller. These items 

CANNOT

  

be exchanged with alternative products.

3

  All wiring and hook-ups 

MUST

 be installed by a 

licensed electrical or general contractor. Electrical 
work 

MUST

 be done in accordance with the 

National Electrical Code and local ordinances, 
regulations and codes.

4

  All devices communicate via a pre-configured, 

wireless network – there’s no need for additional 
wiring or knowledge of networking equipment.

5

  Adequate ventilation 

MUST

 be provided to 

ensure the ambient air temperature near the 
Warmsource-E does not exceed 90ºF (32ºC) 
during operation.

6

  Reference the Electro Boiler Manual for allowable 

mineral levels and water quality. Filtered water or  
a corrosion inhibitor may be required.

7

  Installation of a floor drain below the boiler is 

highly recommended.

8

  The Constant Pressure Circulation pump inside 

Warmsource-E adjusts flow rates depending on 
the needs of each zone.

9

  When plumbing for the system is complete,  

operate WCS in “Construction Mode” (pg. 8).  
This feature allows installers to test the boiler 
and flow rates, acclimate building products and 
provide heat on cold job sites.

10

 Disable Construction Mode before installing 

actuators, Manifold Controller(s) or thermostats.

Warmboard Comfort System (WCS) 

MUST

  

be installed by a licensed general contractor,  
heating professional or plumber. 

Failure to use 

a properly licensed installer, failure to use the 
required parts and components and/or any  
deviation from these installation guidelines will 
void any product warranty.

Review this guide and the supplied working 
drawings (including floor plan dimensions)  
before work begins.

Review this guide and the supplied working 
drawings (including the floor plan dimensions) 
before work begins.

DO NOT

 revise tubing loops or zones without 

consulting Warmboard. Field changes will impact 
operation of the system.

Содержание Comfort System

Страница 1: ...For use with Warmsource E electric boiler WARMBOARD COMFORT SYSTEM 0622 Installation Guide...

Страница 2: ...e the ambient air temperature near the Warmsource E does not exceed 90 F 32 C during operation 6 Reference the Electro Boiler Manual for allowable mineral levels and water quality Filtered water or a...

Страница 3: ...s list can be a helpful when working with Warmboard S and WCS f Foundation and joist f Install Warmboard S f Install tubing some loops before walls f Frame walls roof sheeting f Install tubing manifol...

Страница 4: ...be reset with a bike pump and ball valve in the closed position f Backflow preventer required by code in many jurisdictions prevents water in the closed loop system from mixing with the domestic wate...

Страница 5: ...e piping can be found in the WCS Design Drawings f Pressure test all distribution lines for 15 minutes at 100 PSI International Mechanical Code section 1208 1 Minimum Clearances This illustration show...

Страница 6: ...it Air Eliminator 51 2 331 2 33 4 41 2 253 8 1 11 4 conduit 1 2 3 4 conduit 131 4 51 2 21 4 61 8 3 41 8 91 2 Pressure Relief Drain connection 3 4 NPT 1 11 4 conduit Air Eliminator 51 2 331 2 33 4 41 2...

Страница 7: ...all studs then fasten the unit into place Warmsource E weighs 155lbs and requires two individuals to move safely Connections f Plumb the cold water line to the backflow preventer and the pressure redu...

Страница 8: ...nue filling the system with water for 10 15 minutes until no air is seen or heard escaping the hose f Close the fast fill lever then slowly close hose bib A f Ensure the pressure gauge located inside...

Страница 9: ...lug the white Construction Mode jumper into the Sensor 2 terminal The boiler temperature can be adjusted if a higher temperature is desired Warmsource E will reach the target temperature in about 10 m...

Страница 10: ...per heating zone f 120 VAC Manifold Controller one per manifold f 24 volt solenoid valve actuators one per loop f Smart Reset Controller inside Warmsource E Installing the MC f Use the provided screws...

Страница 11: ...m to behave inaccurately If there are any discrepancies regarding the thermostat or zoning contact us immediately f Remove the appropriate thermostat from the box f Grip the face of the thermostat by...

Страница 12: ...connection AC1 Fan on the Smart Reset Controller SRC f Connect the wires from the AC unit to the terminal block accordingly RC 24 volt power red wire Y Cooling Call yellow wire G Fan green wire f To...

Страница 13: ...nutes the green lights will turn blue indicating that the actuators have opened and water is flowing to the zone f If something does not appear to be working properly consult your Warmboard Engineered...

Страница 14: ...EXCLUDED FAILURE TO INSTALL WARMBOARD PRODUCTS ACCORDING TO MANUFACTURER S INSTRUCTIONS WILL VOID ALL APPLICABLE WARRANTIES IT IS EXPRESSLY UNDERSTOOD THAT WARMBOARD IS NOT RESPONSIBLE FOR ANY CONSEQU...

Отзывы: