890405_d•en•2015-12-01
We reserve the right to carry out improvements
95
Menu item
Setting range Description
Display scenes
Display product settings
Display sensor alloca-
tion
Display battery status
NOTE
In this menu, you can define what information and menus are displayed dur-
ing normal operation. In the dealer mode, all menus are always displayed.
9.1.3.14 product settings
Menu item
Setting range Description
Run time, up
00:04...04:00
mm:ss
Time that the product requires from the
lower to the upper limit position
Run time, down
00:04...04:00
mm:ss
Time that the product requires from the up-
per to the lower limit position
Automatic calibration,
up
0...10 s
Additional run time of product when the
"Run time up" has ended (additional time
to ensure that the product has opened
completely)
Automatic calibration,
down
0...10 s
Additional run time of product when the
"Run time down" has ended (additional
time to ensure that the product has closed
completely)
Tilting time
0.0...25.0 s
Time that a slat product requires to move
from the minimum to the maximum slat
angle
Minimum slat angle
-127...127°
- - -
Minimum slat angle permitted for the prod-
uct being controlled
Maximum slat angle
-127...127°
- - -
Maximum slat angle permitted for the prod-
uct being controlled
Tilting steps per tilt
1...20
Desired number of steps into which a full tilt
of the slats is subdivided
Change motor polarity
If the up-down direction is reversed, the po-
larity of the motor can be changed without
having to reconnect it.
NOTE
The availability of the individual settings varies with the product type.