890405_d•en•2015-12-01
We reserve the right to carry out improvements
89
9.1.3.3 awn/dusk control
Menu item
Setting range Description
Dawn/dusk control ON/
OFF
Activate/deactivate control function
Adjustable in hand-held
transmitter
Here you can define whether hand-held
transmitters belonging to the network can
be used to influence the control mode
Active/inactive when
absent
The automatic control function depends on
the "absent" variable
Enable time, morn.
Mo-Fr
00:00...23:59 Time in the morning from Mo-Fr at which
the dawn/dusk control is enabled
Enable time, morn.
Sa-Su
00:00...23:59 Time in the morning on Sa-Su at which the
dawn/dusk control is enabled
Enable time, eve. Mo-F
r
00:00...23:59 Time in the evening from Mo-Fr at which the
dawn/dusk control is disabled
Enable time, eve. Sa-Su 00:00...23:59 Time in the evening on Sa-Su at which the
dawn/dusk control is disabled
Limit value, morning
10...500 lx
If this value is reached and exceeded, the
product moves to the defined position and
slat angle
Limit value, evening
10...500 lx
If the measured value reaches the limit
value or drops below it, the product moves
to the defined position and slat angle.
Position
morning
0...100 %
Position to which the product is moved
when the "Morning" limit value is reached
Slat angle, morning
-180...180°
Slat angle to which a slat product is moved
when the "Morning" limit value is reached
Position, evening
0...100 %
Position to which the product is moved
when the "Evening" limit value is reached
Slat angle, evening
-180...180°
Slat angle to which a slat product is moved
when the "Evening" limit value is reached
Measured value, dawn/
dusk
The measured value is loaded from the
actuator when the [
Settings
] menu is
opened. To refresh the display, close the
[
Settings
] menu and open it again.
9.1.3.4 Precipitation monitor
Menu item
Setting range Description
Precipitation monitor
ON/OFF
Activate/deactivate the function
Adjustable in hand-held
transmitter
Here you can define whether hand-held
transmitters belonging to the network can
be used to influence the control mode
Active/inactive when
absent
The automatic control function depends on
the "absent" variable
Main menu
System
Products
Product type
Channel x
Settings
Dawn/dusk control
Main menu
System
Products
Product type
Channel x
Settings
Precipitation monitor
System