1 Quick-Start/Commissioning
Just a few steps are required to start up your W&T Web-Ther-
mometer and to make it visible in your network.
Power-over-Ethernet
The Web-Thermometers are designed for use in PoE (Power-
over-Ethernet) environments in accordance with IEEE802.3af.
Power is provided by the network infrastructure using the RJ45
terminal. The devices support both phantom power using data
pairs as well as power feed using the unused wire pairs s.
Power Supply
).
!
Use of the Web-Thermometer is also possible in networks
without PoE power supply. In this case simply use an external
power supply attached to the screw terminal as described in
the chapter Power Supply. No additional configurations or settings
are necessary.
1.1 Connecting the sensor (#57713, #57714, #57715,
#57720)
IO-Port