4.4.13 &D (AT&C[0|1|2|3])
= Modem response to DTR option
Default setting: 2
Defines the effect of a level change on the DTR input on the
LAN-Modem. One of four functions may be selected:
•
&D0
The LAN-Modem ignores the signal.
•
&D1
If the LAN-Modem is in data mode,k an ON
r
OFF change
places the modem in command mode. The ATO command
can be used to return to data mode.
•
&D2
A change from ON
r
OFF breaks the existing connection.
A new connection can only be established when an enable
level is present on DTR.
•
&D3
Has the same function as &D2 but additionally it resets
the LAN-Modem. If the LAN-Modem is on data mode, a
level change on the DTR input is only recognized if it is
present for the time defined in S-register
25
.
4.4.14 &Fn (AT&F[0|1])
= Restore
The LAN-Modem has two factory settings which can be
invoked using the commands
AT&F
and
AT&F1
. The
defaults specified by the individual commands refers
basically to the factory profile 0. Factory profile 1 differs
here in the function of the DTR input (
&D0
instead of
&D2
)
and in the flow control (
&K0
instead of
&K3
).
Содержание 58210