9.0 INFORMATION REGARDING FAULTS
SILOTOP R03
2
FIL.100.--.M.EN Issue: A2
06.12
51
Problem
Probable cause
Possible remedy
Excessive differential pressure
1) Compressed air supply failure
1) Check the functioning of the
compressor
&KHFNWKHFRQGHQVDWLRQ¿OWHUV
Check the presence of water and/or
RLOLQWKHDLUWDQNRIWKH¿OWHU
2) Lack of air from the blowing pipes
2) Check the proper working of the
electronic panel.
Check the proper working of the
solenoid valve.
Check the proper working of the
solenoid valve membrane
3) Filter elements clogged
3) Operate the unit on empty and
WKHQUHPRYHDOO¿OWHUHOHPHQWVDQG
replace damaged one
Dust in the clean area
&KHFNIRUSRVVLEO\GDPDJHG¿OWHU
elements
1) Replace if damaged
2) Check the seals
2) Replace if damaged
&KHFNLIWKH¿OWHUHOHPHQWVDUH
housed correctly in their seat
3) Install again, in case
Solenoid valve continuous blowing
1) Check the proper working of the
coil
1) Switch on and off the compressed
DLUVXSSO\WRWKH¿OWHUWLPHV
2) Remove the component no. 6 after
removing the relative ring nut.
Unscrew the component 5 ensuring
that the pin and spring inside does
not fall and that the former slides
perfectly in.
3) Inspect pin coupling area of
components 4 to compoment 5
ensuring there are no impurities.
9.1 Trouble-shooting
Minor problems can be solved without consulting a specialist.
The following Table contains a list of the most common problems, the possible causes and possible remedies.
)RUSDUWLFXODUO\GLI¿FXOWDFWLRQVZKLFKDUHQRWPHQWLRQHGLQWKH7DEOHFRQWDFWWKH0DQXIDFWXUHU¶V&XVWRPHU
Service Department.