5.0 INSTALLATION AND FIXING
SILOTOP R03
2
FIL.100.--.M.EN Issue: A2
06.12
26
POWER SUPPLY VOLTAGE
(VAC)
POWER INPUT
(A)
POWER
(W)
24
0.220
5.3
115
0.090
10.4
230
0.050
11.5
260
0.045
11.7
*NQPSUBOU
7KHPDLQSRZHUVXSSO\6PXVWDOZD\VEHSUHVHQWRQWKHSDQHOGHDFWLYDWHRQO\IRUPDLQWHQDQFH
Electronic control panel connection
1) POWER SUPPLY VOLTAGE
- Works with all the supply voltages from 24V to 260V either in AC or in DC.
2) SUPPLY VOLTAGE AUTO-RECOGNITION
- The electronic panel automatically recognises the voltage ap-
plied, therefore no settings are necessary for normal operation.
3) CONNECTIONS TO JUNCTION BOX
- The electronic panel is powered by means of terminal (S1) and ac-
cepts all the voltages mentioned at point 1) above. To switch on the control panel a clean contact (voltage
free) must be connected to the terminal strip S2. When the contact (S2) opens, the end of cycle cleaning
V\VWHPEHJLQVDQGFRQWLQXHVIRUD¿[HGSHULRGRIDERXWPLQXWHVGXULQJZKLFKWKHSUHVHWSDXVHDQG
cleaning times are maintained.
4) WAIT SAFETY BLOCK
- Activation of the WAIT input (closure of contact) suspends the cleaning cycle and
saves the position of the last output activated. The block persists as long as WAIT is active (contact closed).
When WAIT is deactivated (contact open), the cleaning cycle is resumed from the next output to the last
output energized if S2 is still active. Otherwise, the program returns to STANDBY without carrying out the
end of cycle cleaning system. The WAIT contact can be used as safety/alarm switch or to reduce the end
of cycle cleaning system duration. In fact, if WAIT is activated during the end of cycle cleaning system, the
cleaning stops completely; if WAIT is deactivated, the program returns to STANDBY.
Control panel electrical input
The Table of power inputs of the panel in various operating conditions, i.e. according to the supply voltage is
shown below.
TIMER SETTING
PAUSE (sec)
WORK (sec)
END OF CYCLE
CLEANING SYSTEM (min)
MIN.
MAX
SET
MIN.
MAX.
SET
FIXED TIME
5
90
28
0.1
0.3
0.1
10