![WAMGROUP SILOTOP R03 Series Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/wamgroup/silotop-r03-series/silotop-r03-series_installation-operation-and-maintenance-manual_871523016.webp)
SILOTOP R03
3.0 TECHNICAL INFORMATION
2
FIL.100.--.M.EN Issue: A2
06.12
12
3.6 Noise level
The noise level of the
SILOTOP
®
R03 series dust collector does not exceed the limit of the directive 86/188/
CEE and 89/392/CEE.
The measured equivalent continuous A-weighted sound pressure level LAeq is 70.0 dB(A).
All readings were taken at 1 metre distance from the equipment at 1.6 metres from ground, with compressed
air shots at 6 bar each 28 seconds, using a precision sound level meter.
Noise measurements of installed equipment may vary due to site conditions.
%BOHFS8BSOJOH
Depending on the installation site, the installer must adopt suitable systems (barriers, etc.), if neces-
VDU\WRPDLQWDLQWKHQRLVHOHYHOVZLWKLQWKHOLPLWVSHUPLWWHGE\ODZ
3.7 Environmental operating limits
8QOHVVRWKHUZLVHVSHFL¿HGWKHHTXLSPHQWFRQFHUQHGPD\EHXVHGRQO\ZLWKLQWKHOLPLWVLQGLFDWHG
- Altitude: less than 1,000 m at sea level
- Environmental temperature: between - 20 °C and + 40 °C
- Cold climates: with temperature less than 5 °C use oil and lubricants suitable to the operating temperature.
Generally protect the equipment appropriately according to the prevailing conditions.