9.0 INFORMATION REGARDING FAULTS
SILOTOP R03
2
FIL.100.--.M.EN Issue: A2
06.12
51
Problem
Probable cause
Possible remedy
Excessive differential pressure
1) Compressed air supply failure
1) Check the functioning of the
compressor
Check the condensation filters
Check the presence of water and/or
oil in the air tank of the filter
2) Lack of air from the blowing pipes
2) Check the proper working of the
electronic panel.
Check the proper working of the
solenoid valve.
Check the proper working of the
solenoid valve membrane
3) Filter elements clogged
3) Operate the unit on empty and
then remove all filter elements and
replace damaged one
Dust in the clean area
1) Check for possibly damaged filter
elements
1) Replace if damaged
2) Check the seals
2) Replace if damaged
3) Check if the filter elements are
housed correctly in their seat
3) Install again, in case
Solenoid valve continuous blowing
1) Check the proper working of the
coil
1) Switch on and off the compressed
air supply to the filter 3-4 times.
2) Remove the component no. 6 after
removing the relative ring nut.
Unscrew the component 5 ensuring
that the pin and spring inside does
not fall and that the former slides
perfectly in.
3) Inspect pin coupling area of
components 4 to compoment 5
ensuring there are no impurities.
9.1 Trouble-shooting
Minor problems can be solved without consulting a specialist.
The following Table contains a list of the most common problems, the possible causes and possible remedies.
For particularly difficult actions which are not mentioned in the Table, contact the Manufacturer’s Customer
Service Department.
Danger - Warning
Before carrying out any operation “set the equipment (machine) concerned in safety” (see “Glossary
and terminology”), operate according to the indications on the “Operation and Maintenance Manual”
and in accordance with and in compliance with the standards in force as regards health and safety.
Jamieson Equipment Company | 5314 Palmero Court | Buford, GA 30518 | 800.875.0280 | [email protected]