6.0 INFORMATION REGARDING USE
SILOTOP R03
2
FIL.100.--.M.EN Issue: A2
06.12
42
6.1 Production start-up
Before starting up the filter, the operator in charge and authorized for the production must ensure that the
safety devices installed are present, in working order and that the operating conditions are respected (hatches
closed, inlet and outlet).
Start-up procedure
Proceed as follows (after preliminary checks):
1)
Start up the dust discharger (if present)
2)
Start up the air compressor.
3)
Start up the control panel (MS LED ON).
4)
Start up the cleaning cycle (clean LED ON)
5)
Check all solenoid valves to ensure they work correctly (the yellow LED goes on when the board sends the
impulse to the solenoid valve)
6)
Check the cleaning cycle duration and the pause time.
Frequent checks of the filter operation
particulary during the first few weeks
are essential.
Only through these checks it will be possible to determine whether the preset pause duration is the proper one
as regards the cleaning of the filter cartridges.
Important
In case of excessive noise, strong vibrations, etc. stop the filter cleaning system and report the prob
-
lem to the person in charge authorized to restore the correct working.
Do not use the equipment if damaged.
6.2 Equipment shutdown at the end of the work cycle
1)
Switch off the filter without disconnecting from the mains (according to the wiring diagram instructions
inserted in the panel, the timer is automatically activated for further after-shut-down cleaning cycle of 10
minutes).
2)
After other 10 minutes, disconnect the controller from the mains.
3)
Switch off the compressor.
4)
Switch off the dust discharger valve or screw conveyor (if present).