SILOTOP R03
3.0 TECHNICAL INFORMATION
2
FIL.100.--.M.EN Issue: A2
06.12
16
Other hazards
HAZARD DAMAGE CAUSE
SAFETY MEASURES
LEGAL
REFERENCE
OPERATING
INSTRUC-
TIONS
RESIDUAL
RISKS
Electricity
Electric
shock
caused
by direct
contact
The
junction
box was
opened
All interventions on the elec-
tric parts have to be carried
out only by authorized and
specialized personnel. Befo-
re operating on these parts,
disconnect from all mains
supply and prevent with the
proper devices an accidental
reconnection.
EN 292-1
NO
Static
electricity
Electric
shock
caused
by direct
contact
Contact
with
metallic
parts
The dust collector shall have
an effective, proper earthing
which has to be periodically
checked.
EN 292-1
NO
Fitting
errors
Not applicable
Extreme
tempera-
ture
Not applicable
Fire
Materials
handled
It is not allowed to handle
materials which might
involve such risks. The plant
Manufacturer or the plant
fitter shall set up appropriate
devices.
EN 292-1
NO
Explosion
Biological
(viral/
bacterial)
Noise
Hearing
loss
Exposure Noise is according to the
norm
EN 292-1
NO
Vibrations
Inappro-
priate
fixing
Fix the equipment to the
ground or to a steady struc-
ture
EN 292-1
NO
Slip, trip
and falls
Not applicable
Mainte-
nance
Falling
objects
Fixing
and/or
mainte-
nance
opera-
tions to
the filter
compo-
nents
The electrician/ plant fitter
has to provide platforms or
walkways and to dispose
access structures. The usa-
ge of mobile platforms and
the appropriate measures to
prevent the falling of objects
according to the legislaltion
in force have to be indicated
in the Manual too.
EN 292-1
NO
Jamieson Equipment Company | 5314 Palmero Court | Buford, GA 30518 | 800.875.0280 | [email protected]