M40
1 / ENGLISH
INSTALLATION INSTRUCTIONS
Under 1500 m
Over 1500 m
SPACE HEATER LOCATION
1.Free distance from the surrounding walls as
shown in fig. 1.
2.The spaces between the walls must be kept
clean and free from dust, litter and foreign
objects.
3.The air inlets of the lower part of the heater
jacket at the front, sides and back must be
kept free from objects and hindrances pre-
venting air intake.
4.There must not be any surfaces, construc-
tions or objects presenting fire hazard or pre-
venting the heat flow directly above the hea-
ter closer than 1 metre from the top of the
heater. Fig. 1.
5.The heater must be properly fastened by
screws to the floor or to its foundation casing,
which is also fastened to the floor. The equip-
ment must be in vertical position. Fig. 2.
6.The heater must be placed so that no water
can drip, flow or splash into it.
7.The maximum lenght of uninsulated exhaust
pipe is 3 m, insulated 6 m.
8.If needed notice the change of air density by
changing mountain parameters on the elec-
tronics (PCB), when the heater is situated
over 1500 m altitude above the sea level for
example on an arctical hill.
Fig. 1.
Fig. 2.
Fig. 3.
T0209