M40
5 / ENGLISH
TECHNICAL DETAILS
CHECK-LIST AT SERVICE FAILURES
The fuel is not moving:
The movement can
be checked by lifting the suction hose out of
the tank for a few seconds; there will be an air
bubble moving with the fuel.
- Check the tightness of the joint: if necessary,
make the joint tighter.
- Check the hose: replace a leaking hose with
a new one.
- Make sure that the pump receives voltage;
the pumping sound or voltage variation when
measuring the voltage.
No voltage is received:
the yellow light is not
on.
- Check the charging of the battery.
- Check the connections of the battery or po-
wer-supply unit.
- Check if the automatic fuse has tripped and
come up, press it down if necessary. Check
the main fuse connected to the electric con-
ductor and replace it if necessary.
Under-voltage:
the yellow light is blinking.
- Charge the battery or replace it with a more
powerful one.
- Replace the electric conductors with thicker
ones; see installation instructions.
Too much fuel is received:
the heater is over-
heated and cuts off its function by itself.
- Check that the fuel surface of the tank is be-
low the lower surface of the heater
- The exhaust gas or fire ventilation hose is
blocked.
- Remove obstacles and blockages
Fuel and voltage is received normally, but
the device will not start:
- Check through the inspection port whether
the glow plug is glowing at start-up, change
it if necessary.
- Check the fuel composition and if there is any
suspicion that water may have condensed
into the tank, remove the water; see mainte-
nance instructions.
N.B. The device cannot be re-started until the
red and yellow signal lights have gone out.
If necessary, contact the nearest Wallas servi-
ce or your supplier.
Fuel:
Furnace oil / Diesel oil (anti-freezing proper-
ties according to the operating conditions) or
paraffin (kerosene)
Fuel consumption:
M40: 0.16 - 0.4 litres/hour = 3.8 – 9.6 litres/
day
Thermal power:
M40: 1600 – 4000 W
Power adjustment:
Stepless manual adjustment or room thermos-
tat
Starting:
By manual switch or automatic, weekly timer
(additional equipment) or by remote control
starter (additional equipment)
Operating voltage:
12 V. Power source: battery or Wallas power-
supply apparatus equipped with a 12 V/15 Ah
mini battery.
Current consumption:
0.2 – 0.4 A = 4.8 – 9.6 Ah/day
Heater current 8 A for 4.5 minutes after start-
up.
Dimensions and weight:
M40 730 x 440 x 240 mm / 25.5 kg
OPERATION INSTRUCTIONS
T0209