5
- All Other Markets
NOTE:
(*) Measure Burner operating pressure at manifold test point with two burners operating at
'High Flame' setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted,
unless when converting between gases, if required.
(**) TOWN GAS Only - Adjust burner operating pressure using adjustable gas regulator
supplied.
Refer to ‘Gas Conversion and Specifications' section in this manual for further details.
Gas supply connection point is located at rear of appliance, approximately 130mm from right hand
side, 32mm from rear and 655mm from floor (55mm for bench top –
B m odels) and is reached
from beneath appliance. (Refer to
‘
Dimensions
’
section). With exception of RN8200G-B and RN8203G
-B models which are 100mm from right hand side, 32mm from rear and 70mm from floor.
Connection is ½" BSP male thread (for RN8200G and RN8203G models).
Connection is ¾" BSP male thread (for all other models).
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
28 MJ/hr
- each 300mm Griddle Section
21 MJ/hr
21 MJ/hr
Supply Pressure
1.13 - 3.40 kPa
0.75 - 1.50 kPa
Burner Operating Pressure (*)
0.95 kPa
0.63 kPa
Gas Connection
See
‘
Gas Connection
’
information below.
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
- each 300mm Griddle Section
21 MJ/hr
Supply Pressure
2.75 - 4.50 kPa
Burner Operating Pressure (*)
2.6 kPa
Gas Connection
See
‘
Gas Connection
’
information below.
Содержание RNL8200G Series
Страница 8: ...6 Refer to Page 9 for Cooktop options Rating Plate Location for this option R R...
Страница 32: ......