23
NOTE:
These conversions should only be carried out by qualified persons. All connections must be
checked for leaks before re-commissioning the appliance.
Adjustment of components that have adjustments / settings sealed (e.g. paint sealed) can only be
adjusted in accordance with the following instructions and shall be re-sealed before
re-commissioning this appliance.
For relevant gas specifications refer to
‘Gas Specifications Tables’
at end of this section.
1.
Remove the pot stands, burner caps and burner bodies and the pot stand supports.
2.
Remove injectors and replace with correct size injectors as shown in
‘
Gas Specifications Tables
’
at
end of this section.
3.
Refit the pot stand supports,
pot stands, burner caps and
burner bodies.
4.
Re-light main burners and
check flame size on simmer
(LOW) position.
Adjust low fire adjustment screw on open burner gas control valves to
obtain desired flame size.
NOTE: The 'Low Fire Screw' should be sealed with coloured paint on
completion of low fire adjustment.
Low Fire Screw
For F Options Only,
Unscrew and remove Main Injectors.
For PF Options Only,
Unscrew and remove Main and
Pilot Injectors.
Содержание RNL8200G Series
Страница 8: ...6 Refer to Page 9 for Cooktop options Rating Plate Location for this option R R...
Страница 32: ......