11
NOTE:
It is most important that this Cooktop is installed correctly and that operation is correct
before use. Installation shall comply with local gas, health and safety requirements.
This appliance shall be installed with sufficient ventilation to prevent the occurrence of
unacceptable concentrations of health harmful substances in the room, the appliance is
installed in.
Waldorf Cooktops are designed to provide years of satisfactory service, and correct installation is essential
to achieve the best performance, efficiency and trouble-free operation.
This appliance must be installed in accordance with National installation codes and in addition, in
accordance with relevant National / Local codes covering gas and fire safety.
Australia / New Zealand:
- AS/NZS5601
- Gas Installations.
United Kingdom:
- Gas Safety (Installation & Use) Regulations 1998.
- BS6173
- Installation of Catering Appliances.
- BS5440 1 & 2
- Installation Flueing & Ventilation.
Ireland:
- IS 820
- Non - Domestic Gas Installations.
Installations must be carried out by qualified service persons only. Failure to install
equipment to relevant codes and manufacturer
’
s specifications shown in this section will void
the warranty.
Components having adjustments protected (e.g. paint sealed) by the manufacturer are only
to be adjusted by an authorised service agent. They are not to be adjusted by the installation
person.
Remove all packaging and transit protection from appliance including all protective plastic coating
from exterior stainless steel panels.
Check equipment and parts for damage. Report any damage immediately to the carrier and
distributor.
Report any deficiencies to distributor who supplied appliance.
Check available gas supply is correct to that shown on Rating Plate attached to underside of R/ H
side, front Cooktop lower trim, for Bench, Cabinet Base and Leg Stand Models. For Refrigerated
Base Models, rating plate is located inside right hand front panel and can be viewed through upper
grille.
1.
Installation must allow for a sufficient flow of fresh air for the combustion air supply.
2.
Installation must include adequate ventilation means, to prevent dangerous build up of combustion
products.
3.
Never directly connect a ventilation system to appliance flue outlet.
4.
Position appliance in its approximate working position.
5.
All air for burner combustion is supplied from underneath appliance. Legs must always be fitted and
no obstructions placed on underside or around base of appliance, as obstructions will cause incorrect
operation and / or failure of appliance.
NOTE: Do not obstruct or block appliance flue. Never directly connect a ventilation system to
appliance flue outlet.
Combustion Air Requirements:
RN8200G
RN8400G
RN8600G
RN8800G
Natural Gas (G20)
12m
3
/hr
24m
3
/hr
36m
3
/hr
48m
3
/hr
LPG / Propane (G31)
13m
3
/hr
25m
3
/hr
38m
3
/hr
50m
3
/hr
Содержание RNL8200G Series
Страница 8: ...6 Refer to Page 9 for Cooktop options Rating Plate Location for this option R R...
Страница 32: ......