26
- Australia
- New Zealand
- United Kingdom
Category:
II
2H3P
(20, 37).
Flue Type:
A
1.
NOTE: Measure burner operating pressure at manifold test point with two burners operating at full setting.
Operating pressure is ex-factory set, through appliance regulator and is not to be adjusted, apart from
when carrying out Gas Conversion, if required. (Refer to ‘Gas Conversion’ section for details).
Open Burner
Main Burner Injectors
Ø 2.30mm
Ø 1.40mm
Pilot Burner ('PF' Models only)
0.30
0.20
Griddle
Main Burner
Ø 2.10mm
Ø 1.30mm
Pilot Burner
0.35
0.23
Burner Aeration Setting
Fully open
Fully open
Supply Pressure
20 mbar
37 mbar
Burner Operating Pressure (*)
9.5 mbar
26 mbar
Gas Regulator Cap Screw
Open Burner
Main Burner
Ø 2.45mm
Ø 1.50mm
Pilot Burner ('PF' Models Only)
0.30
0.20
Griddle
Main Burner
Ø 2.10mm
Ø 1.30mm
Pilot Burner
0.35
0.23
Burner Aeration Setting
Fully open
Fully open
Supply Pressure
1.13 - 3-40 kPa
2.75 - 3-40 kPa
Burner Operating Pressure (*)
0.95 kPa
2.6 kPa
Gas Regulator Cap Screw
Open Burner
Main Burner
Ø 2.45mm
Ø 1.40mm
Pilot Burner ('PF' Models Only)
0.30
0.20
Griddle
Main Burner
Ø 2.10mm
Ø 1.30mm
Pilot Burner
0.35
0.23
Burner Aeration Setting
Fully open
Fully open
Supply Pressure
1.13 - 3-40 kPa
2.75 - 3-40 kPa
Burner Operating Pressure (*)
0.95 kPa
2.6 kPa
Gas Regulator Cap Screw