8. What to do if?
Problem
Possible causes
Corrective action
Luminaire is not lit.
Mains plug not
plugged in.
X
Plug the mains plug into a
socket.
The plug in the light
head has not been
connected correctly.
X
Check the plugs in the light
head.
LED module is defec-
tive.
X
Contact our service team.
Luminaire does not
respond to inputs.
Software function is
defective.
X
Restore the factory setting of
the luminaire. For this purpose
read the operating instructions
of POWER control, which can
be found in the service area of
our homepage www.waldmann.
com.
The luminaire is flash-
ing when switched on.
The light control is
being configured.
X
Wait until the luminaire is lit per-
manently.
Indirect light and
direct light are
switched on with a
time delay.
The light control is
being adjusted.
X
Wait until the luminaire is lit per-
manently.
The light does not
switch off automati-
cally even if the light
intensity in the room
is sufficient due to
daylight or other light
sources.
The light control is not
active.
X
Activate the light control, see
The light control has
been calibrated while
the room was illumi-
nated by daylight or
other light sources.
X
Calibrate the light control, see
chapter 7.4 “Calibration of the light
The luminaire head is
not aligned correctly.
The luminaire head
is not adjusted opti-
mally.
X
Adjust the light head, see chap-
ter 3.4 “Mounting the luminaire
The connecting cable
is damaged.
Mechanical impact on
the connecting cable.
X
Disconnect a damaged connect-
ing cable immediately from the
power supply and have it replaced
by the manufacturer or by a skilled
electrician.