manualshive.com logo in svg
background image

Installation Guide

IND676 | DOC-2002763

Lumination

®   

LED Luminaire

LPL Gen D Series

BEFORE YOU BEGIN

Read these instructions completely and carefully.

Save These Instructions

Use only in the manner intended by the manufacturer.
If you have any questions, contact the manufacturer.

Prepare Electrical Wiring

Electrical Requirements

• The LED luminaire must be connected to the mains

supply according to its ratings on the product label.

• Class 1 wiring should be in accordance with NEC.

This device complies with Part 15 of the FCC Rules. Operation is

subject to the following two conditions: (1) This device may not cause

harmful interference, and (2) this device must accept any interference

received, including interference that may cause undesired operation.

CAN ICES-005(A)/NMB-005(A)

Grounding Instructions

• The grounding and bonding of the overall system

shall be done in accordance to local electric code of

the country where the luminire is installed.

Note: 

This equipment has been tested and found to comply with the

limits for a Class A digital device, pursuant to part 15 of the FCC 

Rules.

These limits are designed to provide reasonable protection against

harmful interference when the equipment is operated in a commercial

environment. This equipment generates, uses, and can radiate radio

frequency energy and, if not installed and used in accordance with

the instruction manual, may cause harmful interference to radio

communications. Operation of this equipment in a residential area

is likely to cause harmful interference in which case the user will be

required to correct the interference at his own expense.

WARNING / AVERTISSEMENT

RISK OF ELECTRIC SHOCK

• Turn power off before inspection, installation or removal.

• Properly ground electrical enclosure.

RISK OF FIRE

• Follow all NEC and local codes.

• Use only UL approved wire for input/output connections.

Minimum size 18 AWG (0.75mm2).

• Do not install insulation within 3 inches (76 mm) of luminaire top.

RISQUES DE DÉCHARGES ÉLECTRIQUES

• Coupez l’alimentation avant d’inspecter, installer ou déplacer le luminaire.

• Assurez

-

vous de correctement mettre à la terre le boîtier d’alimentation électrique.

RISQUES D’INCENDIE

• Respectez tous les codes NEC et codes locaux.

• N’utilisez que des fils approuvés par UL pour les entrées/sorties de connexion.

Taille minimum 18 AWG (0.75mm2).

• Maintenir une distance de 76 mm (3 pouces) entre le luminaire et l’isolant.

1

Содержание GE current Lumination LPL Gen D Series

Страница 1: ...mits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to ca...

Страница 2: ...sing LPL24x Series Bend the brackets on the housing to make sure they hook to T Bar Secure safety cable to connection hole as needed to meet local seismic requirements Safety cable and method of attachment to the building are provided by contractor according to local building codes T Bar 3 Insert luminaire into T bar ceiling grid Unit should not move freely within the ceiling grid To ensure a cons...

Страница 3: ...kout hole equipped with an appropriate wire restraint or cable gland Then re attach and fix electrical enclosure cover with screw by screwdriver Option Follow diagram for 0 10V Run wires from controller through a different knockout than the AC input wire At the output side of fixture make appropriate connections by using UL listed connectors or wire nuts To combine with LFAMBA0VQFAEL LCAMBA0NRFAEL...

Страница 4: ... nuts for 18 14 AWG Connect the ground wire to the green yellow ground wire of luminaire When connecting dimming controller wires must run through a separate knockout hole equipped with an appropriate wire restraint or cable gland Then re attach and fix enclosure cover with screw by screw driver www gecurrent com 2020 Current Lighting Solutions LLC All rights reserved GE and the GE monogram are tr...

Отзывы: