![Waitzinger THP 125/42 R 4 XXT Скачать руководство пользователя страница 68](http://html1.mh-extra.com/html/waitzinger/thp-125-42-r-4-xxt/thp-125-42-r-4-xxt_user-manual_869133068.webp)
C
ONTROLS
AND
DISPLAYS
C
HAPTER
5
THP 94/42 R 4 XXT
THP 125/42 R 4 XXT
THP 140 H/42 R 4 XXT
GB-07.2005
5-10
5.13
Emergency Stop button
Emergency Stop buttons are fitted to the truck-mounted concrete pump
at the following places:
墌
Control panel desk
墌
Outrigger control block, right
墌
Boom control block
墌
Radio remote control
墌
Outrigger control block, left
墌
Cable remote control
5.14
Control elements on the hydraulic block
3
4
2
1
7
5
6
1
Valve Y5b
2
Push button
3
Valve Y3
4
Pressure sensor
5
Valve Y5a
6
Valve Y4a
7
Valve Y4b
Fig. 5.14 Hydraulic block
Fig. 5.13 Emergency Stop button