Daily
Maintenance work
Maintenance intervals
W
eekly
Every
500 operating hours
Every 1,000 operating
hours or annually
After the first
50 operating hours
Check the structural steelwork of the boom, boom mounting and outriggers for cracks.
Replace the filter cartridges in the hydraulic oil tanks for the boom and concrete pump.
Clean the magnetic rod.
Perform a wear check on the S-valve, verify 8 mm wall thickness.
Check the oil level in the transfer shift gearbox.
Perform a wear check on the conveying cylinders.
Clean the diesel pre-filter on the vehicle.
Check that the conveying piston fastenings are tight.
Check the operation of all safety equipment such as Emergency Stop, grill and guards.
Completely drain the hydraulic oil, flush out the hydraulic oil tank and fill with the necessary
quantity of hydraulic oil, see section 9.7.3.
Check the pressure setting of the pump and distributor boom against the data sheet, see
sections 3.3 and 3.4.
Check engine speed and operation of the pump together with stroke rate against the data
sheet, see sections 3.3 and 3.4.