background image

352-353.805.006 

16

 

Date: 2019-07-02 

Radio Control

 

WARNING! This equipment can cause radio interference, make sure this equipment respects 
all national and local regulations before use. 
 
CAUSION: Change or modifications not expressly approved by the party responsible for 

compliance could void the user’s authority to operate the equipment.

 

 
The product has a build-in in CRMX wireless DMX to control the operation, and the radio device 
uses the 2.4 GHz band as accepted in Europe and USA. For other locations and national restrictions 
consult your national authority. 

FCC Statement 

This equipment generates, uses and can radiate radio frequency energy and, if not installed and 
used  in  accordance  with  the  instructions,  may  cause  harmful  interference  to  radio 
communications.  However,  there  is  no  guarantee  that  interference  will  not  occur  in  a  given 
installation. If this equipment does cause harmful interference to radio or television reception, 
which can be determined by turning the equipment off and on, the user is encouraged to try to 
correct the interference by one or more of the following measures: 
 

 

Reorient or relocate the receiving antenna. 

 

Increase the separation between the equipment and receiver. 

 

Connect the equipment into an outlet on a circuit different from that to which the 
receiver is connected. 

 

Consult the dealer or an experienced radio/TV technician for help. 

FCC ID: XRSCRMXNOVA101 
IC: 8879A-CRMXN101 
 
 

Tips for reliable radio transmission 

 

Do a range check before each live event, and make sure the range limitation is not exceeded. 

 

Power off unused wireless devices on the 2.4GHz band to minimize the risk of a signal “lock

-

out” 

during use. 

 

Tips for reliable data transmission 

 

Use shielded twisted-pair cable designed for RS-485 devices: standard microphone cable cannot 
transmit control data reliably over long runs. AWG24 cable is suitable for runs up to 100 meters 
(328 ft.). 

 

Never split a DMX line without using an opto-isolated RS-485 splitter/amplifier. 

 

Terminate the link by installing a termination plug in the output socket of the last product. The 
termination plug, which is a male XLR plug with a 120 Ohm, 0.25 Watt resistor soldered between 

pins 2 and 3, “soaks up” the control signal so it does not reflect and cause interference. If a splitter 

is used, terminate each branch of the link. 

 

 

 

Содержание 352.701

Страница 1: ...S VEJ 3 TELEPHONE 45 86 18 14 20 8270 H JBJERG EMAIL sales wahlberg dk DENMARK Track Runner Series User Manual Cogwheel Item No 352 701 Fast Motor 352 702 Slow Motor Friction Wheel Item No 353 701 Fas...

Страница 2: ...parts PROTECTION FROM INJURY Fasten the product securely to a fixed surface rig or structure as described in this manual Ensure that any supporting hardware can hold at least 10 times the weight of al...

Страница 3: ...HE TRACK 14 MOUNTING THE LOAD 15 DATA LINK 15 RADIO CONTROL 16 TIPS FOR RELIABLE RADIO TRANSMISSION 16 TIPS FOR RELIABLE DATA TRANSMISSION 16 CONNECTING THE WIRELESS DATA LINK 17 CHANGING TRANSMITTER...

Страница 4: ...353 FW is Class II from rail power DMX control signal DMX 512 6 channels used DMX connection 5 pole XLR male not used female Wireless 2 4 GHz ISM Band 100mW CRMX inside Load Capacity 50 kg 110 lb Pull...

Страница 5: ...352 353 805 006 5 Date 2019 07 02 Drawings Track Runner Cogwheel 352 More detailed drawings can be found in Appendix 1 on page 25...

Страница 6: ...352 353 805 006 6 Date 2019 07 02 Track Runner Friction Wheel 353 More detailed drawings can be found in Appendix 2 on page 26...

Страница 7: ...board mounting bracket power and DMX outlets it is easy to attach any DMX unit you would like to control from the moving element It runs on a UniBeam track system in a horizontal orientation with no l...

Страница 8: ...owering operating or servicing the product Before applying power Check the Wahlberg Motion Design website at www wahlberg dk for the most recent documentation and technical information about the produ...

Страница 9: ...running meter of a solid track However this may vary depending on the weight and distribution of the load Consult Wahlberg Motions Design for further guidance and customized solutions like floor stand...

Страница 10: ...55 Passive runner Heavy Duty 385 kg 848 lb load G No end stop option 344 710 Adjustment tool I for aligning the gear rack across tracks joints 344 711 Tools for track assembly 186 Wireless transmitter...

Страница 11: ...ed for each customized installation like for other safety factors or when using a passive runner with heavy loads Consult your Wahlberg distributor or Wahlberg Motion Design for any questions A2 B C E...

Страница 12: ...ent any moving element to leave the track during normal operation Also the rod B shall be mounted in the correct position depending on the left or right end of the track A WARNING Always secure the tr...

Страница 13: ...n the EU the cables must be HAR approved or equivalent and in the USA minimum hard usage type SJT or equivalent If you install a power plug on the power cable install a grounding type earthed plug tha...

Страница 14: ...UE1 power input plug A Using the rotary switch B to select mode 4 for mounting from the right forward of the track as recommended and shown or mode 2 for mounting from the left reverse Make sure to pu...

Страница 15: ...required in order to control the product via the Wireless DMX transmitter A ordered separately or a cable carrier E to the Track Runner B The unit have a 5 pin XLR connector C for DMX data output con...

Страница 16: ...ference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit...

Страница 17: ...ted Note that for mode 0 to 6 no DMX signal is needed thus the DMX lamp will blink but the unit will operate as desired Changing transmitter station To change the transmitter station 1 Press the LINK...

Страница 18: ...oving right see from the connection side as for installation without DMX applied 5 Manual up fast 6 None Track Runner is stopped 7 DMX slow position ramp For normal operation of the unit and the slow...

Страница 19: ...l 4 is put back at 0 Note that it should be moved gradually towards 0 to give the motor time to slow down The left position should be set with channel 4 before the right position is set with channel 5...

Страница 20: ...nd the soft limit left and right positions have been saved Finally the position control with channel 1 and 2 is now relative to the left and right position adjusted It is recommended to set the soft l...

Страница 21: ...l 3 is set above zero and therefore this channel works as a main brake Duty cycle When the unit is continually operated for more than 30 minutes at full load speed and high ambient temperatures the be...

Страница 22: ...the units will tend to follow that fade When fading the positions 1 The speed channel should be a set to 100 to gain the highest possible speed 2 The position channel should be added as a 16 bit chan...

Страница 23: ...aintenance can be provided by the Wahlberg Motion Design giving owners access to Wahlberg Motion Design s expertise and product knowledge in a partnership that will ensure the highest level of perform...

Страница 24: ...wear and tear Through improper use and the excessive use of force the encoding lugs and guide slots in the connector system can become so severely worn or damaged that it is possible to insert the ca...

Страница 25: ...352 353 805 006 25 Date 2019 07 02 Appendix 1 Dimensions Track Runner CW Cogwheel FRONT VIEW FRONT VIEW WITH TRACK TOP VIEW SIDE VIEW...

Страница 26: ...352 353 805 006 26 Date 2019 07 02 Appendix 2 Dimensions Track Runner FW Friction Wheel FRONT VIEW FRONT VIEW WITH TRACK TOP VIEW SIDE VIEW...

Страница 27: ...352 353 805 006 27 Date 2019 07 02 Appendix 3 Power Connectors...

Страница 28: ...352 353 805 006 28 Date 2019 07 02...

Страница 29: ...utput Power out powerCON TRUE 1 Power in 100 240 VAC powerCON TRUE 1 DMX signal out XLR 5 pole Control input DMX signal Microcontroller Motor controller Power supply DMX signal in XLR 5 pole 2 4GHz Ba...

Страница 30: ...352 353 805 006 30 Date 2019 07 02 This page is intentionally left blank...

Страница 31: ...352 353 805 006 31 Date 2019 07 02 This page is intentionally left blank...

Страница 32: ...the desired LEFT end position is reached 9 Pull channel 5 to 20 the unit starts moving forward right 10 Stop the unit pull channel 5 to 0 when the desired RIGHT end position is reached 11 Pull channe...

Отзывы: