74
Reference AT Commands
WAGO-I/O-SYSTEM 757
757-801 Bluetooth® Module RS-232
Manual
1.0.0
If a value is set that cannot be applied, the WSA uses the next smallest valid
value.
Example:
AT ECO TXPWR DEF = 4
9.5.5.2
AT ECO TXPWR MAX
This command queries (
AT ECO TXPWR MAX ?
) or determines
(
AT ECO TXPWR MAX = <max. transmit power>
) the maximum
transmit power the WSA uses initially to search for other devices or immediately
after establishing a connection. This value (in dB) cannot be smaller than the
value for the transmit power initially used for device discovery or after
establishing a connection.
Example:
AT ECO TXPWR MAX = 4
9.6
AT HELP
The
AT HELP
command lists the syntax of all available AT commands and
command groups. The character conventions for all available “HELP” commands
are described in the section “Configuration”> … >“Basic Structure of Replies to
AT Commands.”
Output:
00 SUCCESS
Attaching “HELP” to any AT command followed by “...”
will list the syntax of the concerning command group in
detail. Available commands:
AT HELP
AT
AT BTID ...
AT BTSEC ...
AT CON ...
AT ECO ...
AT INFO
AT INQ ...
AT LOGOUT
AT RDEV ...
AT RESET
AT STATUS ...
AT SYS ...
AT UART ...
>