WAGO I/O SYSTEM 750 XTR
Device Description
23
750-610/040-000 Power Supply 24 VDC Fuse Diagn XTR
Manual
Version 2.0.0
3.6
Technical Data
3.6.1
Device Data
Table 8: Technical Data
– Device
Width
12 mm
Height (from upper edge of DIN-rail)
62.6 mm
Depth
100 mm
Weight
46.8 mm
Degree of protection
IP20
3.6.2
Supply
Table 9: Technical Data
– Supply
Current consumption,
system voltage
max.
5 mA
Voltage supply via CAGE CLAMP
®
connectors
under laboratory conditions
for ambient operating temperature
−40 °C … +55 °C
for ambient operating temperature
+55 °C
… +70 °C
24 VDC (power supply via SELV/PELV
power supply unit)
18 V … 31,2 V (17,4 V … 31,2 V)
1)
18 V … 28,8 V (17,4 V … 28,8 V)
1)
18 V … 26,4 V (17,4 V … 26,4 V)
1)
Voltage via power jumper contacts
24 VDC
Current via power jumper contacts
max.
6.3 A
Rated surge voltage
1 kV
Supply voltage detection level
ON:
OFF:
> 15 V DC
< 5 V DC
Fuse
5 × 20 mm; T 6.3 A
(Fuse not included)
Use UL recognized fuses only!
1)
Including residual ripple of 15 %
3.6.3
Communication
Table 10: Technical Data
– Communication
Data width
2 bits:
1 bit current monitoring
1 bit fuse default