6.5
LOCATION OF THE CONTROL UNIT
All sealed elements on the control unit must be present and undamaged. During operation,
all electric connections of the control unit have to be tightly sealed with the corresponding
plug connectors or closing elements. While under voltage, neither plug connectors nor
closing elements may be separated or opened.
Incorrect installation of the device!
Explosion hazard and damage to the device.
Set up the device outside the spray booth / spray zone.
If possible, set up the device outside the Ex zone (Ex zone 2 is
permissible).
Protect the device from signifi cant temperature and moisture
changes.
Protect the device from contamination.
Lay and fi x the connecting cable correctly.
Ensure that the local mains voltage and tension of the device
match.
DANGER
Sparks form when live components are separated or connected!
Explosion hazard from electric sparks.
Do not disconnect plug connections under voltage.
Do not open fuse holders under voltage.
Do not remove the service plug cover under voltage.
WARNING
Impurities in the spraying system!
Spray gun blockage, products harden in the spraying system.
Flush the spray gun and paint supply with a suitable fl ushing agent.
NOTICE
Содержание VM 5000
Страница 2: ......
Страница 42: ...42 VM 5000 OPERATING MANUAL EDITION 08 2014 ORDER NUMBER DOC2318718...
Страница 65: ...65 VM 5000 OPERATING MANUAL EDITION 08 2014 ORDER NUMBER DOC2318718...
Страница 66: ...66 VM 5000 OPERATING MANUAL EDITION 08 2014 ORDER NUMBER DOC2318718...
Страница 67: ...67 VM 5000 OPERATING MANUAL EDITION 08 2014 ORDER NUMBER DOC2318718...