Installation of an on / off valve (2) for the start / stop operation:
If an on / off valve (2) for the normal start / stop operation is necessary, the on / off valve
must be installed after the fi lter pressure regulator (4) so that the air supply (3) for the pilot
valves is not interrupted. The control of the on / off valve can be made locally or remotely.
B_04207
1
2
3
4
Installation of the air cut-off valve (1) for the emergency stop:
For the PM500 double diaphragm pump, an external air cut-off valve (1) must be installed
before the fi lter pressure regulator (4) for the emergency stop is installed.