OPERATING MANUAL
VERSION 01/2013
ORDER NUMBER DOC 2335747
Double diaphragm pump - operating principle
The double diaphragm pump is driven with compressed air.
Two diaphragms (A) are mechanically connected to each other by means of a shaft (B).
Each diaphragm generates two chambers: pumping chamber (P) and motor chamber (M).
A pneumatic distributor alternately supplies compressed air into one of the driving
chambers (M), thus producing the diaphragm's movement and consequently causing one
of the pumping chambers (P) to empty (as a result of volume decrease), while at the same
time the other chamber (P) sucks the fl uid in (as a result of volume increase). A series of four
non-return valves (C) prevents the liquid from fl owing back, thus producing the suction
and delivery phases in each pumping chamber, and generating the pumping eff ect.
The PM500 models are equipped with a safety valve that opens when the maximum
allowed value of compressed air supply is exceeded.
5.4
MODE OF OPERATION
Overpressure!
Risk of injury from bursting components.
Never change the safety valve setting.
WARNING