33
B_03234
R max < 1 M
Ω
OPERATING MANUAL
EDITION 05/2015
ORDER NUMBER DOC2319150
Control unit
Grounding
cable
Spraying stand
Floor, static dissipative
Work piece
Pump or
pressure tank
Paint tank or
tank for return
fl ow
Grounding scheme (example)
Conveyor
Mains cable
Minimum cable cross-section
Control unit
4 mm2 / AWG 12
Product supply
Paint tank
Conveyor
16 mm2 / AWG 6
Booth
Spraying stand
Grounding of spray gun
The spray gun is grounded via the spray gun cable.
The GM 5000EAC spray gun must be connected by the gun cable with the VM 500 or
VM 5000 control unit.
Note for the sprayer
Safety shoes and gloves, if used, must be static dissipative.
Содержание GM 50000EAC
Страница 2: ......
Страница 30: ...30 OPERATING MANUAL EDITION 05 2015 ORDER NUMBER DOC2319150...
Страница 47: ...47 B_03162 1 2 3 4 5 6 7 8 10 9 Y 11 1 OPERATING MANUAL EDITION 05 2015 ORDER NUMBER DOC2319150...
Страница 53: ...53 OPERATING MANUAL EDITION 05 2015 ORDER NUMBER DOC2319150...
Страница 62: ...62 OPERATING MANUAL EDITION 05 2015 ORDER NUMBER DOC2319150...
Страница 102: ...102 OPERATING MANUAL EDITION 05 2015 ORDER NUMBER DOC2319150 15 4 EC TYPE EXAMINATION CERTIFICATE...
Страница 103: ...103 OPERATING MANUAL EDITION 05 2015 ORDER NUMBER DOC2319150...
Страница 104: ...104 OPERATING MANUAL EDITION 05 2015 ORDER NUMBER DOC2319150...
Страница 106: ...106 OPERATING MANUAL EDITION 05 2015 ORDER NUMBER DOC2319150...
Страница 107: ......