26
Cobra 40-10/2K
.
B_03120
V
B_03119
6A
6B
5B
5A
7B
7A
1
2
8
9
3B
3A
4B
4A
OPERATING MANUAL
EDITION 10/2010
PART NO. DOC322871
5.2.2
BASIC CLEANING
1. Place empty container (5a and 5b) under return tubes (4a and
4b).
2. Place suction hoses (7a and 7b) in a containers with solvent (6a
and 6b).
3. Set pressure regulator (1) to approx. 0.05 MPa; 0.5 bar; 7.25 psi.
4. Open return valves (3a and 3b).
5. Slowly open ball valve (2).
6. Adjust the air pressure on the pressure regulator (1) so that the
pump runs regularly.
7. Rinse the system until clean solvent fl ows into the containers (5a
and 5b).
8. Close ball valve (2).
9. Switch over return valves (3a and 3b).
10. Point the gun (8), without nozzle, into container (5) and open it.
11. Slowly open ball valve (2).
12. Rinse until clean solvent fl ows from the gun.
13. Close ball valve (2).
Note
:
During cleaning proce-
dure briefl y push the
valve pushers (V).
Содержание Cobra 40-10
Страница 2: ......
Страница 49: ...49 Cobra 40 10 2K B_03133 13 14 15 15 A A A B B 16 16 B OPERATING MANUAL EDITION 10 2010 PART NO DOC322871...
Страница 53: ...53 Cobra 40 10 2K OPERATING MANUAL EDITION 10 2010 PART NO DOC322871...
Страница 57: ...57 Cobra 40 10 2K OPERATING MANUAL EDITION 10 2010 PART NO DOC322871...
Страница 59: ......