Filling hydraulic stage with oil
Procedure
1. Pump as in the fi gure down shown on the head place.
2. Unscrew threaded plug (5).
3. Unscrew 2 lock screws (4) and replace it through the fi ttings straight (6) from the oil
fi lling kit.
4. Connect hoses with Y- pieces (7).
5. Fill syringe (8) with hydraulic oil and put in at hose.
6. Drive piston (9) into front end position. Filling oil with catheter-shot into oil bowl (3)
until oil fl ows out of the oil suction nipple free of blow holes.
7. Drive piston (9) into rear end position. Filling oil with catheter-shot into oil bowl (3)
until oil fl ows out of the oil suction nipple free of blow holes.
8. Refi ll oil approx. 19 mm; 0.75 inches up to oil level A (oil level before exhaust).
9. Screw in threaded plug (5) and tighten lightly. Put pump on the side and remove oil
fi lling kit. Screw in 2 lock screws (4) with seals and tighten.
SIHI_0109_GB
CAUTION
Environmental pollution by waste oil!
Waste oil in the duct system or buried in the soil leads to heavy
environmental damage
Groundwater contamination is punishable
Collect waste oil and return it at punblic collecting point .
Waste oil is taken back with the purchase of hydraulic oil by the
salesman .